Factory:   Super control

OFF, Supervision, Super control

This option is used to set and enable/disable 
internet supervision.

This  option  allows  you  to  set  the  time  zone  if  the 
boiler is in a different time zone than the web portal 
server. (this option must be set if you enable "Time 
syncronisation option")

This option allows you to reset connection with 
home network.

This  option  allows  you  to  enter  the  name  of  WiFi 
home network to which you want to connect the "Cm 
WiFi box" and the boiler. You must enter exact WiFi 
network name or else boiler will not able to connect to 
the WiFI network.

This option allows you to enter a password for your 
home Wi-Fi network. You must enter exact password 
or else boiler will not be able to connect to the WiFi 
network.

This option allows boiler time synchronization with 
web server time (internet time).

Internet supervision

Technical instructions CONTROL UNIT

 BioTec Plus

34

Summary of Contents for BioTec Plus

Page 1: ...tel 385 40 372 600 fax 385 40 372 611 ENG THE FIRST START UP MUST BE DONE BY AUTHORIZED PERSON OTHERWISE PRODUCT WARRANTY IS NOT VALID READY TECHNICAL INSTRUCTIONS Description and use of BioTec Plus...

Page 2: ...s in software update mode this option can be used only by an authorized person If this happens it is necessary to turn o the main switch and restart without any pressure on the screen After turning on...

Page 3: ...d by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Protective gloves are obligatory Check whether boiler and equipment are installed and connected in acc...

Page 4: ...chamber temperature 12 Flue gas temperature 13 The percentage of oxygen in the flue gases lambda probe 14 Boiler side activity indicator 15 Wood pellet tank 16 Boiler temperature Wood pellet firing si...

Page 5: ...does not work if all the conditions for its operation are not met for example low temp in the boiler otherwise works normally SYMBOLS Automatic ue gas tubes cleaning Flue pass Cleaner additional equip...

Page 6: ...laying parameters can be changed regardless of boiler working phase and which fuel are choosen as active for work 1a WOOD w menu changeable menu menu for using parameters at wood firing left side of t...

Page 7: ...work Button BOILER OPERATION DISPLAY options graphic numeric Button ENTER Button BACK Button PREVIOUS SCREEN Button NEXT SCREEN Button OK Navigation buttons LEFT RIGHT UP DOWN Button DELETE Button FAC...

Page 8: ...these two side are active which fuel are choosen Active side have green indicator inactive side have red indicator red x On figure above is example for switching from left side of the boiler to the r...

Page 9: ...w Taking over submenu b through main screen by pressing boiler side status indicator a activating Taking over option through main menu In main menu menu WOOD w see Point 1 0 Main menu page 6 choose s...

Page 10: ...ed Do you want to ENABLE pellets take over Confirm it by pressing Confirm button Hold this button for 3s Taking over INDICATION THAT TAKING OVER IS ACTIVATED OR SWITCHED TO THE PELLET SIDE BASED ON TA...

Page 11: ...ed primary secondary is positioning themselves Waiting for the Tfg 50 C When Tfg 50 C a The user can con rm the message IGNITION 2 3 then screen will show the message IGNITION 3 3 which user also can...

Page 12: ...llow you to move to the next stage SD6 DX or if the conditions are not satisfy writes an error and stops the operation of the boiler SD6 Set the power blades for D6 if the required position primary se...

Page 13: ...ler automatically start again GLW1 Shutting down the boiler for keeping the glow GLW2 Phase of keeping the glow GLW3 Glow blowout in phase of keeping the glow GLW4 Start a new lling set the primary se...

Page 14: ...his stage grate cleaning stage starts C0 and enters S7 3 stage Burner does not work standby pause Boiler waits demand for start Stage after power supply failure and power supply return el heater is st...

Page 15: ...ct Protective gloves must be used Protective gloves must be used NOTE Before ignition make sure that is left side of the boiler selected like active see indicator A on figure below for procedure for c...

Page 16: ...detailA cover the wood logs with fine chopped wood use enough fine chopped wood to cover wood logs below height of fine chopped wood layer must conform a approx height of first row of wood logs cover...

Page 17: ...layed message IGNITION 2 3 on this step is necessary to wait until flue gas temperature raise 50 C middle boiler door must be opened all time when is flue gas temperature higher than 50 C press enter...

Page 18: ...ary to press button Because ignition phase is on proces display will be displayed current ignition step to 1 By pressing button we return to full preview of ignition phase 1 1 Use the left side of the...

Page 19: ...aining only glow in the fuel loading chamber In this step is necessary to open upper boiler door and check if it glow quality good enough for firing continue and refilling wood loading chamber or it i...

Page 20: ...e pages 4 and 5 in Technical instructions for BioTec Plus boiler BOOK 1 2 align the glow with scraper based on estimates of glow quality and amount of glow put more or less dry thin wood depend about...

Page 21: ...isplay is displayed boiler operating phase OFF 3 Go to the ignition phase like is described in point 2 1 IGNITION in this technical instructions PROCEDURE IF GLOW IS NOT ENOUGH GOOD If glow is not eno...

Page 22: ...gloves must be used Protective gloves must be used NOTE Before ignition make sure that is right side of the boiler selected like active see indicator A on figure below for procedure for choosing boile...

Page 23: ...OFF button After pressing ON OFF button on display will be displayed window for boiler stop confirmation Press OK to confirm boiler stop D5 D5 D5 D5 Use the right side of the boiler Fuel Wood pellets...

Page 24: ...art see figure below It s necessary to open casing cover using the handle IMPORTANT At filling wood pellet tank it must be filled at least 2 3 of capacity for correct work of wood pellet level sensor...

Page 25: ...Fuel Wood SUBMENUS 1 w Boiler temperature In this submenu is possible to adjust boiler working temperature Factory adjusted 85 C Adjustment range 75 C 90 C 2 w Differential Boiler In this submenu is p...

Page 26: ...ture Factory adjusted 50 C Adjustment range 40 C 80 C 5 Differential of DHW depend about DHW configuration In this submenu is possible to adjust differential of domestic hot water temperature Factory...

Page 27: ...Factory adjusted 80 C Adjustment range 40 C 85 C 3 p Differential buffer tank temperature In this submenu is possible to adjust differential for buffer tank temperature Factory adjusted 10 C Adjustme...

Page 28: ...thout maintaining the glow so that the next time you can continue working with the newly added fuel without the need for a new ignition Mode of operation with the Glow option after the ignition is mad...

Page 29: ...Pellets p Fuel WOOD w Submenus in Operation menu depend of the enabled options in Installation menu and depend of the select side of the boiler wood or pellet Operation Technical instructions CONTROL...

Page 30: ...order to check their function MANUAL TEST IS POSSIBLE ONLY WHEN THE BOILER IS SWITCHED OFF Submenus in Manual test menu depend of the enabled options in Installation menu and depend of the select sid...

Page 31: ...passage cleaner A 6 1 2 FLUE PASS CLEANER ADDITIONAL EQUIPMENT 6 1 1 SCREW REFILL ADDITIONAL EQUIPMENT This option allows you to check the motor device of screw refill It is necessary to press the ST...

Page 32: ...time of the screw refill See technical manual PELLETTANK CPSP BP 800 for details This option is used to ON or OFF the screw refill Factory ON Possible selection ON OFF Operation Technical instruction...

Page 33: ...g router because manual setting of network parameters is not possible For more informations contact administrator of your home network To be able to use Cm WiFi box on BioTec Plus boiler minimum requi...

Page 34: ...th home network This option allows you to enter the name of WiFi home network to which you want to connect the Cm WiFi box and the boiler You must enter exact WiFi network name or else boiler will not...

Page 35: ...e details on how to connect the CSK Touch see Technical instructions for installation use and maintenance CSK Touch digital room corrector 7 0 CSK Touch additional equipment only for authorized servic...

Page 36: ...tain actions that are factory enabled for all digital room correctors can be disabled on an individual digital room corrector For each corrector can be enabled disabled CSK Touch view con guration Boi...

Page 37: ...By pressing OK button error window will be minimized and showned on main display 8 1 ERRORS WARNINGS INFORMATIONS ON THE MAIN SCREEN Errors warnings are recorded in history see point 8 2 History 1 2 3...

Page 38: ...e first press on the field error warning information field is indicated in addition to see and date generated errors warnings information The second press on the selected error warning information pri...

Page 39: ...f is installed Possible causes Interruption on el connections between sensor and boiler CM2K cold connection or invalid outside temperature sensor Outside temperature sensor error Possible causes Inte...

Page 40: ...tor failure E19 Sensor CM2K 2 circuit Boiler status Pump of 2 heating circuit doesn t work Boiler work normally Possible causes Error on ow temperature sensor of 2 heating circuit on regulator CM2K E2...

Page 41: ...or of 4 heating circuit on regulator CM2K E20_1 Corrector CM2K 4 circuit Boiler status Pump of 4 heating circuit work in intervention mode by heating curve Boiler work normally Possible causes Error o...

Page 42: ...K regulator bad corrector connection to the CM2K or room corrector failure E19_3 Sensor CM2K 8 circuit Boiler status Pump of 8 heating circuit doesn t work Boiler work normally Possible causes Error o...

Page 43: ...en any door or opening on boiler Interruption in el connection between safety pressure switch and boiler connection to the boiler cold connection or invalid safety pressure switch Interruption or bad...

Page 44: ...o to phases S7 C0 and OFF Possible causes Interruption on el connections between sensor and boiler connection to the boiler cold connection or invalid sensor Boiler status Boiler go to phases S7 C0 an...

Page 45: ...gas sensor Low return temperature Low bu er temperature WOOD FIRING WARNINGS WARNING NAME DESCRIPTION Boiler working wood side upper boiler door is opened and ue gas temperature is too high It s neces...

Page 46: ...enough for short time Wp13 Fuel level Upper boiler door are opened wood side during burner work wood pellet side if time counter expire then will be showned error Ep46 Wp15 Upper door opened wood side...

Page 47: ...3 Bad ignition Iw4 O during stabilization Iw6 Glow after power up Iw7 O after power up WOOD PELLETS FIRING INFORMATIONS INFO NAME Ip8 Re ll Ip9 Flame disappeared in ignition phase Ip9_1 Retry ignition...

Page 48: ...hoice of language regulation when you turn on main switch If is marked OFF after turning on the main switch it will be set on before selected language and after some time display will show the work di...

Page 49: ...played on the screen Memory 1 2 3 Pressing one of the three offered buttons will display the message Save current settings On the screen Pressing the OK button will save the current controller setting...

Page 50: ...Notes Technical instructions CONTROL UNIT BioTec Plus 50...

Page 51: ...Notes Technical instructions CONTROL UNIT BioTec Plus 51...

Page 52: ...385 40 372 622 fax 385 40 372 621 Company assumes no responsibility for possible inaccuracies in this book originated typographical errors or rewriting all the pictures and diagrams are principal and...

Reviews: