CENTENT COMPANY
SPECIFICATIONS
MIN
MAX
UNITS
ELECTRICAL
Supply Voltage
18
80
VOLT (DC)
Current (continuous)
--
20
AMP
Step Pulse Frequency
0
1
MHz
Opto-isolator
current
10
10
mA
Encoder
Frequency
0
200 kHz
Servo Lock Range
-128
+128
COUNTS
Signal
Level
TTL
encoder
0
5
VOLT
(DC)
analog
encoder
-1
+1
VOLT
(DC)
Supply
Current
+5
Volt
Supply
--
100 mA
-5
Volt
Supply
--
50
mA
ENVIRONMENTAL
Operating temperature -20
75
°C
-4
167
°F
Humidity 0
100
%
Shock --
100
G
MECHANICAL
Weight 17
19
ounce
482
539
gram
Terminal Screw Torque
4.5
lb/in
Size (LxWxH)
4.75 x 4.00 x 0.85
inch
121 x 102 x 22
millimeter
Mounting hole centers
3.625 x 3.625
inch
92 x 92
millimeter
Mounting screw size
6
8
#
31
Summary of Contents for CN0182