Assembly and operating instructions
CENTAX-N
033N-00035…00075-F.00
M033-00002-EN
Rev. 2
CENTA Antriebe Kirschey GmbH
43 / 47
9.5
Dismantling the hub (if necessary)
Dismantle the hub as appropriate for the supplied design (see installation
drawing):
Dismantling the hub with keyway, see chapter 9.5.1 .
Dismantling the hub with conical oil interference fit, see chapter 9.5.2 .
Dismantling the CENTA-conical clamping hub, see chapter 9.5.3 .
9.5.1
Dismantling the hub with keyway
See Fig. 6-2:
Remove the hub (3) from the shaft (A).
9.5.2
Dismantling the hub with conical oil interference fit
See Fig. 6-3:
WARNING
Injury and material damage can occur as a result of:
Non-compliance with the operating instructions for the hydraulic
pumps
Before carrying out work with the hydraulic pumps, do not fail to read
their operating instructions. Only ever work with hydraulic pumps as
described in their operating instructions.
WARNING
Injury and material damage can occur as a result of:
Hydraulic fluid spraying out
Use protective goggles.
WARNING
Injuries and material damages can occur by:
Suddenly loosening hubs
Secure the hub with a hydraulic tool against sudden axial loosening.
IMPORTANT
We recommend the following mounting fluids:
For mounting:
Oil with a viscosity 300 mm
2
/s at 20°C, e.g. SKF LHMF300
For dismantling:
Oil with a viscosity 900 mm
2
/s at 20°C, e.g. SKF LHDF900