Assembly and operating instructions
CENTAX-N
033N-00035…00075-F.00
M033-00002-EN
Rev. 2
CENTA Antriebe Kirschey GmbH
38 / 47
IMPORTANT
Ensure during installation that the bushes are in the right position.
Consider following table.
Turn the adapter (1.4) towards the pre-mounted rubber element assembly
(C/D), so that the drillings for the bushes (d and n) are aligned in the both
parts (see previous table).
Push the bushes (1.7; 2x180°) into the drillings (d) of the adapter (1.4) and
the drillings (n) of the pre-mounted rubber element assembly (C/D).
Screw together the pre-mounted rubber element assembly (C/D), the bushes
(1.7) and the adapter (1.4) with screws (1.10), washers (1.14) and nuts
(1.13).
Screw together the pre-mounted rubber element assembly (C/D) and the
adapter (1.4) with screws (1.7), washers (1.14), rings (1.3) and nuts (1.13).
6.9
After completed mounting
WARNING
Injury and material damage can occur as a result of:
Loose screw connections
Before commissioning, the tightening torque levels of all screws must
be checked and corrected if necessary.
Before commencing long-term operation, the plant must successfully complete a
test run.