Before servicing or maintenance, stop the motor and disconnect the plug
from the electric source.
After first 10 operating hours, proceed with sump oil
change, as follows:
(Ref. to Fig. 26a and 26b)
– Remove the cap with the magnetic insert (21).
– Remove oil filler cap (07).
– Make sure that all the oil comes out by slightly tilting
the drill.
– Clean up the cap (21) (see §
11.1.2
).
– Reassemble the cap (21).
– Fill the sump with oil to the level indicator (see §
11.1.1
)
using the oil supplied with the drilling machine; it will
be necessary to use about 140 ml oil.
– Replace the filler cap (07).
Ensure that disposal of used oil is in
accordance with current legislation.
11.1) ORDINARY MAINTENANCE OF THE DRILL
Every 20 hours of operation
11.1.1) Topping up oil
(Ref. to Figs. 26a and 26b)
With the drill switched off and placed on a flat surface,
check the oil level in the crankcase by looking through
the appropriate transparent inspection cover (13). The
level must be approximately half way up the cover; if
the level is low top up the oil by unscrewing the cover
(07) at the top of the crankcase and adding the quantity
of oil required.
Only use the oil grade recommended in § 1.
Never use regenerated or used oil.
The oil must be clean.
11. MAINTENANCE
FIG. 26b
FIG. 26a
13
07