![CellarCool MAGNUM H.E. Owner'S Manual Download Page 52](http://html1.mh-extra.com/html/cellarcool/magnum-h-e/magnum-h-e_owners-manual_2580294052.webp)
Magnum
12000 SPECIFICATIONS
* Sizing the Unit to the Room
The specification chart will provide information on the unit's cooling capacity. There are circumstances in which a cellar design may
require a larger unit due to preexisting design restrictions. Certain building materials such as glass, stone, or concrete may seem
adequate but do not offer the insulation capacity required to maintain the optimum temperature for storing wine. We recommend
purchasing a unit with a larger capacity to compensate for these design limitations. Undersized cooling units can lead to premature
failure and/or prevent the system from reaching the desired set temperature. As a result, they are not covered under warranty.
Model
12000 H.E. Evaporator Unit
(Fan Coil Unit)
H.E.
Condenser
(Air-Cooled Condensing Unit)
Dimensions
Refrigerant
R-134a
Condensing Unit HP
1.5 HP
Voltage Rating
120V (15-amp dedicated circuit required)
Weight (lbs)
96
84
Amps
9.37 Running Amp
Line Set
Liquid line 3/8” OD; Suction line 5/8” OD (less than 50 ft.), 3/4” (greater than 50 ft.)
Drain Line
3/4” ID CPVC
Installation
Condensing unit can be installed up to 100 line feet from the evaporator unit.
Thermostat
KDT- Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable), 24V - Customer supplied
Temp. Delta
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty
Two-year limited warranty (parts and labor)
BTU/h (60°F condenser air
intake temperature)
BTU/h (75°F condenser air
intake temperature)
BTU/h (85°F condenser air
intake temperature)
12147/14576
12187/14256
11704/13844
H.E. Condenser (Air-Cooled
Condensing Unit)
29.5”L x 30.9”W x 19.8”H
31.18"L x 10.75”W x 23.25"H
220V (15-amp dedicated circuit required)
LRA 23.6, RLA 5.76, FLA 6.6