background image

1. GENERAL INFORMATION

Thank you for your purchase of CEL-MAR Company product. This product has been completely tested and is covered by two year 

warranty on parts and operation from date of sale.

If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48

41 362-12-46 or e-mail [email protected].

1.1. WARRANTED INFORMATION 

The 

ADA-13040MG 

converter is covered by a two year warranty from date of sale.  In case of being damaged it will be repair or the 

damaged component will be replace. The warranty does not cover damage caused from improper use, materials consumption or any 

unauthorized changes.  If the product does not function (is damaged), or not operate in accordance with the instructions, will be 

repaired or replaced.
All warranty and no warranty repairs must be returned with paid transport and insuring to the 

CEL-MAR Company.

CEL-MAR Company 

under no circumstances won't be responsible for ensuing damage from improper using the product or as a result  

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company

 is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing 

from using or the impossibility of using this product.
In specific cases

 CEL-MAR Company

 discontinue all warranties and in particular do not follow the user manual and do not accept  

terms of warranty by the user.

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged  so 

as not to be exposed to trampling, attaching, or pulling out of the circuit. 

Do not put device on the wet surface.

Do not connect devices for nondescript powering sources,

Do not damage or crush powering wires.

Do not make connection with wet hands.

Do not adapt, open or make holes in casings of the device!

Do not immerse device in water or no other liquid.

Do not put the fire opened on device sources: candles, an oil lamps and the like.

Complete disable from the supply network is only after disconnecting the power supply circuit voltage. 

Do not carry out the assembly or dis-assembly of the device if it is enabled. This may result to short circuit and damage the device.

1.3. CE LABEL

CE symbol on organizing the company CEL-MAR a conformity of the device to the directive of the electromagnetic  

EMC 

2004/108/WE

  (Electromagnetic  Compatibility Directive).  The declaration  of the agreement  is  accessible  through  the 

contact with the technical service at the address e-mail: [email protected] or on the phone at the +48 41 362-12-46.

1.4. ENVIRONMENTAL PRESERVATION

This label on the device inform about putting expended device with other waste materials. Device should send to the  

recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND MAINTENANCE

The ADA-13040MG converter does not require the servicing and maintenance.

Technical support is available at 48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail [email protected].

2. PRODUCT INFORMATION

The Converter is delivered with: User Manual, antenna and ADANet software CD.

2.1. PROPERTIES

Functioning on ETHERNET network- IEEE 802.3 standard,

10/100BaseT physical layer,

Baud rate 10/100Mbps (auto-sensing),

Full or half duplex (auto-sensing) operates mode,

Protocols: TCP, UDP, DHCP, SNMP, SSL/TLS, Telnet, Rlogin, LPD, HTTP/HTTPS, SMTP, ICMP, IGMP, ARP,

Integrated WWW sever for converter configuration,

Configuration of net services according to user personal setting,

Static or dynamic IP address (added by DHCP verver),

Diagnostics of serial and network port,

Encoded transmission: DES (56-bit), 3DES (168-bit), AES (128/256-bit),

Functioning in modes: virtual serial port, serial bridge TCP, serial bridge UDP, TCP sockets, UDP sockets, MODBUS Data 

Gateway,

Functioning on 2 and 4 wire line on RS485 network,

Functioning on 4 wire line on RS422 network,

RS485/RS422 baud rates (bps): 50, 75, 110, 134, 150, 200, 300, 600, 1200, 1800, 2400, 4800, 9600, 14400, 19200, 28800, 

38400, 57600, 115200, 230400,

RS485/422 data format - Number of data bits: 5, 6, 7, 8; Parity checking: None, Odd, Even, Constantly 1, Constantly 0; Stop Bits: 

1, 2,

Transparent for all protocols, which the data format is compatible with the above specifications of RS485/422 interface eg 

MODBUS, DNP, PROFIBUS and others,

Integrated protocols converter MODBUS-TCP to MODBUS-RTU/ASCII (MODBUS Data Gateway),

4

ADA-13040MG

Summary of Contents for ADA-13040MG

Page 1: ...User manual ADA 13040MG ETHERNET to RS485 RS422 Converter with MODBUS GATEWAY 1 io_ada 13040MG_en_v0 10 ADA 13040MG Copyright 2001 2013 CEL MAR sp j...

Page 2: ...ATION AND MANAGEMENT WITH USE OF INTERNET BROWSER 13 5 3 1 NETWORK CONFIGURATION 14 5 3 2 SERIAL PORT CONFIGURATION 14 5 3 2 1 PORT PROFILE OPERATING MODE 14 5 3 2 1 1 REALPORT VIRTUAL PORT 15 5 3 2 1...

Page 3: ...AL PORT SERVICE REALPORT 24 6 1 VIRTUAL PORT DRIVER INSTALLATION IN WINDOWS XP 24 6 2 REALPORT CONFIGURATION IN WINDOWS XP 25 7 FACTORY DEFAULT 26 8 PROBLEMS 26 9 VERSIONS 27 10 DANE SPECIFICATION 27...

Page 4: ...wer supply circuit voltage Do not carry out the assembly or dis assembly of the device if it is enabled This may result to short circuit and damage the device 1 3 CE LABEL CE symbol on organizing the...

Page 5: ...32 devices operating in half duplex mode to RS485 network constructed on the ADA 13040MG The Converter is adapted to supply an external voltage source fron 10V to 30V and power 3W ADA 13040MG has imp...

Page 6: ...ing the converters form power circuit of devices generate large impulse disturbance like contactors relays inverters 3 1 ASSEMBLING The ADA 13040MG converter case is adapted to assembly on TS 35 DIN35...

Page 7: ...be used for converter configuration Fig 3 Direct connection to PC 3 2 2 CONNECTING FOR REALPORT MODE FUNCTIONING Fig 3 above and 4 5 below show how correctly connect the ADA 13040MG to LAN WAN networ...

Page 8: ...tion to functioning in the TCP UDP serial bridge mode one to one 8 ADA 13040MG Computer with a network adapter Static IP address ADA 13040MG Static IP address ETHERNET Straight cable Table 1 RS485 net...

Page 9: ...ng the ADA 13040MG 9 ADA 13040MG RS485 Bus MODBUS RTU ASCII SWITCH ETHERNET PC with SCADA HMI software M O D B U S T C P ADA 13040MG MODBUS Gateway ADA 13040MG MODBUS Gateway RS485 MODBUS RTU ASCII PL...

Page 10: ...e Connect wires of bus to terminals TX A TX B RX RX like below Fig 10 Connection of the RS485 4W devices to ADA 13040MG 3 3 3 CONNECTION TO 2 WIRE RS485 BUS Most of the devices with RS485 interface us...

Page 11: ...be longer than 3m Observe the polarity connect positive of DC power supplies to V and negative end to V terminal ADA 13040MG has the protection from opposite connection of power supply 4 ACTIVATION If...

Page 12: ...ble port servers Devices Fig 12 To change the network setting of ADA 13040MG should select the Converter from the list Devices and press Configure IP Settings in windows Set IP Address select option A...

Page 13: ...ices with use Internet browser For configuration open the Internet Browser and type the address http converter ip address admin administration htm The login windows will open Enter User name and Passw...

Page 14: ...13040MG converter includes port description setting of port profile operating mode and setting of serial transmission parameters baud rate data bits parity stop bits Select on left panel Configuratio...

Page 15: ...re present on his serial port The drivers RealPort installation is presented in chapter 6 Normally RealPort service allows for one connection through WLAN WAN between computer and server port Connecti...

Page 16: ...ction Establish connection to the following network service enter IP address of device to which TCP client will send data select service and enter port There is also possible to select an option Enabl...

Page 17: ...Apply for save 5 3 2 1 3 1 UDP CLIENT SERVER CONFIGURATION IN CASE OF MASTER DEVICE After saving the UDP Sockets profile will open section UDP Server Settings with operating parameters like on picture...

Page 18: ...ecommended to set parameters like on picture bellow For saving the configuration of UDP client and server for SLAVE device press Apply Fig 20 Example configuration of the UDP server client on converte...

Page 19: ...service server of serial bridge and client in the server port configuration 5 3 2 1 4 1 SERIAL PORT TRANSMISSION PARAMETERS For proper operation of ADA 13040MG with device connected to his RS485 RS42...

Page 20: ...like on Fig 22 and press Apply Then select section Slave Destinations Packet Routing fig below and press Add Section Destination Settings will open Fig 24 Example configuration for communication with...

Page 21: ...maximum delay or gap betweens bytes of a message default 20 ms Message timeout value in ms maximum delay or gap betweens bytes of a message default 2500ms this time must be less than the Timeouts set...

Page 22: ...ttings Global and set option e g as figure below and press Apply Fig 28 Example configuration for communication with MODBUS SLAVE Attention Default port of Industrial Automation Modbus Gateway is 502...

Page 23: ...ine Interface telnet Allow web interface access allow this user to access the web interface for system configuration and management C User Permissions user permissions associated with various services...

Page 24: ...ws2000 Operating systems Drivers WinXP2003Vista_x86_x64 for Windows XP Windows Server2003 Windows Vista Operating systems Installation of Virtual serial port drivers is as follow 1 Connect ADA 13040MG...

Page 25: ...ll be the name ADA 13040MG 5 Double click the name and the window Properties will appear 6 Select Advanced and press Properties 7 New name of virtual port for converter In the window Advanced Properti...

Page 26: ...according to steps below 1 Power OFF the ADA 13040MG 2 Remove the cover of Serial Server Wi Fi connector 3 Press RESET RST and holding the button turn the power on of ADA 13040MG 4 Release the button...

Page 27: ...x0 5 24AWG shield inside large interferences STP Nx2x0 5 24AWG Standards IEEE 802 3 EIA 485 CCITT V 11 Transmission line Asynchronism half duplex or full duplex Optical Signalization PWD green LED pow...

Page 28: ...r of the widest selections of data communications products in the world such as data transmission converters with interface RS232 RS485 RS422 USB Ethernet Wi Fi Current Loop Fibre Optic Converters and...

Reviews: