www.cegasa.com Page -15-
User Manual R10
–
First steps
–
On the last eBick module, fit the bus termination resistor on the connector that is
free.
8. Power connection between modules; First check to see if the installation is in
series or parallel and make sure to use PPE (protective gloves and safety
glasses)
8.1 Parallel connection (voltage 48V) - For eBick P cases (Anderson 350)
✓
Without connecting to the MCP (leave this until last) start connecting all the
power connectors between columns; If there are several columns, use the
PARALLEL POWER CABLE EXTENDER KIT at the rear.
✓
Use the supplied protective cap to protect the power connector left
uncovered on the last eBick module.
BUS termination resistor
POWER EXTENDER KIT
PARALLEL
Anderson connector
SB350