CEDAR DNS3000 dialogue noise suppressor
15
System pages
System Setup Page
This page reports the firmware version and provides access to the various system setup pages.
Fader Calibration Page
Fader calibration is necessary only after a firmware upgrade or after a faulty fader is replaced.
The procedure is as follows:
■
Move all the faders to the bottom of their travel and press ‘-24dB’.
■
Move all the faders to the top of their travel and press ‘+6dB’.
■
Move all the Gain faders to 0dB, and the Level fader to -20dB (i.e. in line with the others)
and press ‘0dB’.
■
The Close button should now be lit. Press this to save the calibration and to close the page.