background image

PAGE 15

Modes of operation

The 

AZX

+ offers two primary modes of operation – 

AUTO

 and 

MANUAL

 – plus a 

quick 

RESET

 facility:

Q

 

AUTO 

mode

Press and rotate the 

ADJUST

 knob until the screen flashes the word ‘Auto’. 

When you release the 

ADJUST

 knob, the central tracking light (in the far left 

of the display) will flash and the unit will be in 

AUTO

 mode.

Q

 

MANUAL 

mode

Press and rotate the 

ADJUST

 knob until the screen flashes the word ‘

USE

r’. 

When you release the 

ADJUST

 knob the unit will be in 

MANUAL

 mode. 

Q

 

RESET

Press and rotate the 

ADJUST 

knob until the screen flashes the word ‘

ZE

ro’. 

When you release the 

ADJUST 

knob, the value in the 

TIME SHIFTER

 will be 

reset to zero. The tracking mechanism will also be reset.

AUTO 

mode

In 

AUTO 

mode, the 

AZX

+ measures the offset between the channels and 

automatically applies a compensating correction to the signal. It is not possible to 
manually alter the amount of correction in 

AUTO 

mode. The central tracking light 

flashes to indicate that 

AUTO 

mode is engaged.

MANUAL 

mode

If you select the 

MANUAL 

mode you will be able to set manually the amount of time 

correction applied to the signal, with a resolution of up to 1% of a sample. You do 
this by rotating the 

ADJUST 

knob until the desired time shift is shown in the display.

Q

 

Coarse and fine adjustment

If, once in 

MANUAL 

mode, you press the 

ADJUST 

knob and then release it 

without rotating it, you will toggle between the 

COARSE 

and 

FINE 

adjustment 

modes. The 

COARSE 

and 

FINE 

indicators in the 

TIME SHIFT

 display will tell 

you which mode you have selected. 
In the 

COARSE 

mode you will shift the timing offset in steps of one sample.

In the 

FINE 

mode you will shift the timing offset in steps of one hundredth of 

a sample (up to 9.99 samples) or one tenth of a sample (from 10.0 to 99.9 
samples).

Note: An integer time shift is equivalent to using an editor to record your signal, 

removing or inserting samples at the start of either the left or right channel, and 
then playing back the file.

Q

 

Tracking lights (

MANUAL

 

mode)

When adjusting the time shift in 

MANUAL 

mode you may wish to monitor the 

tracking lights on the far left of the 

TIME SHIFT

 display. These are telling you 

whether the manually selected time shift is greater than, less than or equal 
to that determined by the autotracking algorithm. 

Summary of Contents for AZX+

Page 1: ...orrector Digital Audio Restoration Modules OWNER S MANUAL 1999 CEDAR Audio Ltd Manual version 1 00 February 1999 interstage Phistersvej 31 2900 Hellerup Danmark Telefon 3946 0000 fax 3946 0040 www interstage dk pro audio with a smile ...

Page 2: ...bstantially in accordance with the appropriate section of its accompanying product manual for a period of one year from the date of supply to the Company s immediate customers 4 2 The Company will make good at its own expenses by repair or replacement any defect or failure that develops in the System within one year of supply to the Company s immediate customer 4 3 The Company shall have no liabil...

Page 3: ... a straight line basis over a one year write off period or b repair or replacement of those components of the System that do not meet the warranties contained within this Document The foregoing states the entire liability of the Company to the Licensee 10 CONSEQUENTIAL LOSS Even if the Company has been advised of the possibility of such damages and notwithstanding anything else contained herein th...

Page 4: ......

Page 5: ...AFETY 3 SETUP 4 AUDIO CONNECTIONS 5 FRONT PANEL INDICATORS AND CONTROLS 7 OPERATING THE BRX DEBUZZER 10 OPERATING THE AZX AZIMUTH CORRECTOR 14 SPECIFICATIONS 18 EMC REGULATIONS 18 PART 2 An introduction to audio restoration BUZZ REMOVAL 20 AZIMUTH CORRECTION 24 ...

Page 6: ......

Page 7: ...PART 1 Operations manual ...

Page 8: ...s in the Series X design and all the units in the family are designed for professional use Additional Series X features include the following Q Flexibility Each model in the Series X range will handle a wide range of audio restoration requirements Q Portability Each Series X is a compact lightweight unit designed to fit a standard 1U rack space Q Audio interfaces Series X incorporates a 24 bit dig...

Page 9: ...afree standingunit thesuppliedrubberfeetshouldbefixedtothe base of the unit Q Power sources The Series X features a universal power supply that will work safely on any mains supply in the ranges 85V to 260V 50Hz or 60Hz AC only The unit should always be grounded or earthed and power connectors should be routed so that they will not be walked on or pinched The Series X is connected to the mains pow...

Page 10: ...n the following Q mains connection lead Q this manual Q rack mounting hardware Q four self adhesive feet Installation site To maintain reliability and prolong operating life observe the following environmental considerations Q the nominal temperature should be maintained between 5 and 35 Celsius Q relative humidity should be in the range 30 to 80 non condensing Q strong magnetic fields should not ...

Page 11: ... output of the Series X should be connected to the SPDIF input of a recording device or external DAC Q Digital AES EBU format audio data The AES EBU format is used by professional digital audio devices You should connect the AES EBU output from your source to the AES EBU input of the Series X using a single cable terminated with an XLR plug The AES EBU output of the Series X should be connected to...

Page 12: ...PAGE 6 CEDAR BRX debuzzer 1 2 3 4 10 11 12 13 14 CEDAR AZX azimuth corrector 1 2 5 6 7 8 9 14 ...

Page 13: ...essor on signals close to full scale may result in slight clipping This can be avoided using the attenuator 4 BRX Process ON OFF and LEDs Q When OUT the input signal is echoed at the outputs Q When IN the processed signal is directed to the outputs Use this control for before after monitoring of the signal The signal delay and attenuation are not affected by this control 5 13 Process controls Refe...

Page 14: ......

Page 15: ...The BRX debuzzer ...

Page 16: ...n level compared with the rest of the signal you should initially set the BUZZ POWER to 12 o clock rather than to maximum If the fundamental frequency is set wrongly then the process will not be able to identify the buzz The FREQUENCY knob has three modes of operation preset value selection fine continuous adjustment and coarse continuous adjustment You may select between them as follows Q Preset ...

Page 17: ... processing would be more effective if 50Hz was correctly selected Tracking indicators The BRX searches for a buzz fundamental in a small window centred on the displayed fundamental frequency The width of this window is approximately 1Hz at a setting of 50Hz and increases with increasing frequency If a consistent buzz is detected within this window one or more of the tracking indicators will light...

Page 18: ...eeds to correctly identify the buzz or hum both in terms of its frequency spectrum and its amplitude It now remains only to determine how much of the noise is removed from the signal Your final step therefore is to reduce the ATTENUATION control turn it anti clockwise to a level just above that at which the buzz becomes audible In doing so you will minimise the possibility of any signal being remo...

Page 19: ...The AZX azimuth corrector ...

Page 20: ...s the timing error To aid rapid setup and accurate processing you can monitor the output Q before or after processing Q in stereo Q with the left and right channels summed mono sum Q with the right channel subtracted from the left mono difference The display indicates the time shift being applied to the signal A positive number indicates that the right channel is being delayed with respect to the ...

Page 21: ... will be able to set manually the amount of time correction applied to the signal with a resolution of up to 1 of a sample You do this by rotating the ADJUST knob until the desired time shift is shown in the display Q Coarse and fine adjustment If once in MANUAL mode you press the ADJUST knob and then release it without rotating it you will toggle between the COARSE and FINE adjustment modes The C...

Page 22: ...or mode PRE POST Q POST The time shift shown in the display is applied to the signal Q PRE The value shown in the display is ignored and the signal is unaffected by the TIME SHIFTER This control allows you to make quick glitch free A B comparisons of the signal before and after azimuth correction Monitor mode STEREO MONO SUM DIFFERENCE Q STEREO The left and right signals from the TIME SHIFTER are ...

Page 23: ...ime relationship using the ADJUST control Do so until you find the TIME SHIFT at which the perceived signal is minimised Hint You can often recognise this by noticing that vocalists and solo instruments disappear from the mix leaving just the reverberation behind 5 Return to STEREO mode and use PRE POST to compare the uncorrected and corrected signals 6 If you are satisfied with the results restar...

Page 24: ...nnectors and good quality shielded cable suitable for digital audio Declaration of conformity Date of issue 1 February 1999 Equipment CEDAR Series X Manufacturer CEDAR Audio Ltd Address 9 Clifton Court Cambridge CB1 7BN UK This is to certify that the aforementioned equipment when used in accordance with the instructions in this manual fully conforms to the protection requirements of the following ...

Page 25: ...PART 2 An introduction to audio restoration ...

Page 26: ... best restored using one of CEDAR s various decrackle time domain processes and we will not consider it further here On the other hand a buzz that has an indistinct time domain structure may be more easily characterised by its harmonic content and then analysed and treated in the frequency domain Historically audio engineers have used a number of conventional filtering techniques to eliminate buzz...

Page 27: ...PAGE 21 Figure 2 Figure 3 Figure 1 ...

Page 28: ...d side effects caused by the first problem you exacerbate the second Thirdly the offending frequencies may not be entirely constant so the filter s teeth may not always be appropriately placed and you will hear the buzz come and go during the course of the material you are playing These problems make comb filters which are nonetheless implemented on a number of audio processing platforms unaccepta...

Page 29: ...PAGE 23 Figure 5 Figure 4 ...

Page 30: ... can be described in its entirety by just three parameters its frequency amplitude and phase The frequency and amplitude describe to a good approximation the perceived pitch and volume of the signal The phase however is of no audible significance until we combine more than one such sinewave For the moment let us consider two sinewaves of the same frequency and amplitude but different phases Figure...

Page 31: ...PAGE 25 Figure 2 Figure 3 Figure 1 Figure 4 ...

Page 32: ...wever none of these attacks the heart of the problem these small but significant non synchronisations of the left and right channels CEDAR corrects these problems by eliminating the timing errors that cause them It does this by identifying any monophonic component in the stereo sound and then measuring the timing difference between the left and right channels of the signal If any such error is det...

Page 33: ...PAGE 27 Figure 6 Figure 5 ...

Page 34: ... CEDAR s processes detect and correct Q The second effect is the smearing caused by the length of tape covered again in the direction of tape travel by the offset head In general terms the head will then average the signal lying underneath it at any point rather than measuring the instantaneous value The degradation caused by this will be smaller than that caused by the primary error and the effec...

Page 35: ......

Page 36: ...factured by CEDAR Audio Ltd 9 Clifton Court Cambridge CB1 7BN United Kingdom Serial number Inspected QC Engineer interstage Phistersvej 31 2900 Hellerup Danmark Telefon 3946 0000 fax 3946 0040 www interstage dk pro audio with a smile ...