background image

NHT UL AF BL

4

Ugolini spa

1 TECHNICAL CHARACTERISTICS

The electric diagram of the dispenser is located in the
inner part of the dispensing side panel.

Specifications are subject to change without notice.

2 INTRODUCTION

Please read all sections of this manual thoroughly to familiarize
yourself with all aspects of the unit.
Like all mechanical products, this machine will require cleaning
and maintenance. Besides, dispenser working can be
compromised by operator’s mistakes during disassembly and
cleaning. It is strongly recommended that personnel
responsible for the equipment’s daily operations, disassembly,
cleaning, sanitizing and assembly, go through these
procedures in order to be properly trained and to make sure
that no misunderstandings exist.

3 INSTALLATION

1 - Remove the corrugate container and packing materials

and keep them for possible future use.

2 - Inspect the uncrated unit for any possible damage. If

damage is found, call the delivering carrier immediately to
file a claim.

3 - Install the unit on a counter top that will support the

combined weight of dispenser and product 

bearing in

m i n d   w h a t   i s   s t a t e d   i n   t h e   p r e c e d i n g   p o i n t   1
IMPORTANT warning.

4 - A minimum of 15 cm (6”) of free air space all around the

unit should be allowed to guarantee adequate ventilation.

5 - Ensure that the legs are screwed tightly into the base of

the machine.
Replace the standard legs originally installed with the 100
mm (4”) legs whenever they are provided with the unit.

6 - Before plugging the unit in, check if the voltage is the same

as that indicated on the data plate. Plug the unit into a
grounded, protected single phase electrical supply
according to the applicable electrical codes and the
specifications of your machine. When the unit has no plug,
install a proper grounded plug, in compliance with
electrical codes in force in your area, suitable to at least
10 Amp 250 Volt (220-230 Volts 50-60 Hz areas) and
2 0 A m p   2 5 0 V o l t   ( 1 0 0 - 1 1 5 V o l t s  5 0 - 6 0 H z   a r e a s )
applications. Should you prefer to connect the unit directly
to the mains, connect the supply cord to a 2-pole wall
breaker, whose contact opening is at least 3 mm. Do not

use extension cords.

7 - The unit doesn’t come presanitized from the factory.

B e f o r e   s e r v i n g   p r o d u c t s ,   t h e   d i s p e n s e r   m u s t   b e
disassembled, cleaned and sanitized. according to this
h a n d b o o k   i n s t r u c t i o n s   ( c h a p t e r
5.3 CLEANING AND SANITIZING PROCEDURES).

4 TO OPERATE SAFELY

1 -

Do not

 operate the dispenser without reading this

operator’s manual.

2 -

Do not

 operate the dispenser unless it is properly

grounded.

3 -

Do not

 use extension cords to connect the dispenser.

4 -

Do not 

operate the dispenser unless all panels are

restrained with screws.

5 -

Do not

 obstruct air intake and discharge openings: 15 cm

(6”) minimum air space all around the dispenser.

6 -

Do not

 put objects or fingers in panels louvers and faucet

outlet.

7 -

Do not

 remove bowls, augers and panels for cleaning or

routine maintenance unless the dispenser is disconnected
from its power source.

NHT 1

P

 UL

NHT 2

 UL

NHT 3

 UL

Transparent removable bowls

n

1

2

3

Capacity of each bowl, approx.

l

10

10

10

Dimensions:

 width

cm

28

36

54

depth

cm

47

47

47

height

cm

69

69

69

Net weight, approx.

kg

26

37

49

Gross weight, approx.

kg

29

40

54

Adjustable thermostats

n

1

2

3

Hermetic compressor

Air-cooled condenser

Overload protector

Safety pressure switch

Noise level lower than 70 dB (A)

IMPORTANT

 

Read electrical ratings written on the data plate of the
individual units; the data plate is adhered on the
dispensing side panel of the unit, just behind the drip
tray (the right side drip tray in multiple bowl models).
The serial number of the unit (preceded by the
symbol #) is adhered inside the left switch box. Data
plate specifications will always supersede the
information in this manual.

IMPORTANT

When handling the machine never grasp it by the bowls
or by the evaporator cylinders. The manufacturer
refuses all responsibilities for possible damages which
may occur through incorrect handling.

ATTENTION

Failure to provide proper electrical ground according to
applicable electrical codes could result in serious shock
hazard.

Summary of Contents for NHT-1P-UL

Page 1: ...O P E R A T O R S M A N U A L MANUAL DE INSTRUCCIONES NHT UL AF ENGLISH ENGLISH ESPA OL B L A C K...

Page 2: ......

Page 3: ...7 5 3 2 CLEANING 8 5 3 3 SANITIZING 9 5 3 4 ASSEMBLY 9 5 4 IN PLACE SANITIZATION 10 5 5 REAR SEAL MAINTENANCE 10 6 ROUTINE MAINTENANCE 10 6 1 MAINTENANCE TO BE CARRIED OUT BY QUALIFIED SERVICE PERSON...

Page 4: ...0 60 Hz areas applications Should you prefer to connect the unit directly to the mains connect the supply cord to a 2 pole wall breaker whose contact opening is at least 3 mm Do not use extension cord...

Page 5: ...d a light switch In addition each bowl is individually operated by a mixer refrigeration switch In fact it is possible to dispense both soft drinks and Granita When a bowl is in Soft Drink mode the be...

Page 6: ...be refilled after the product level drops lower than half of the evaporator cylinder and at the start of each day 7 For good product conservation the dispenser must run overnight at least in Soft Dri...

Page 7: ...I position set mixer refrigeration switch es to I position Soft Drink mode place a pail under each faucet and drain all product from bowls set all control switches to the 0 position 5 3 1 DISASSEMBLY...

Page 8: ...l soap 2 Prepare at least two gallons of a warm 45 60 C 120 140 F sanitizing solution 100 PPM available chlorine concentration or 1 spoon of sodium hypoclorite diluted with half a gallon of water acco...

Page 9: ...the gasket and its front fastening hooks are properly engaged see figure 15 figure 15 8 Use fresh product to chase any remaining sanitizer from the bottom of the bowl s Drain this solution Do not rin...

Page 10: ...it or switch off the 2 pole wall breaker and then remove the panels 2 Annually remove the panels and clean the inside of the machine including the base side panels condenser etc 3 Never remove the ins...

Page 11: ...rotate the timer counterclockwise as this would damage the internal mechanism Align the current time of day with the arrow B on the timer face This is a 24 hour timer showing both A M and P M 2 Progra...

Page 12: ...afety Water Line Solenoid Valve is not used do not use 1 and 2 poles If the remote fill system is equipped with Sold out switches connect their wires to 3 and 4 poles for one bowl unit to 3 4 and 5 po...

Page 13: ...aning Tank to the remote fill system line b Set the unit Power Switch to position I Manually energize the Autofill Device by keeping pushed the Autofill Switch located on the rear cover of each bowl i...

Page 14: ...r s Manual 4 ROUTINE MAINTENANCE Daily inspect the machine for signs of product leaks past seals and gaskets If proper assembly does not stop leaks around seals or gaskets check for improper lubricati...

Page 15: ...et OR 12 22800 24607 Faucet front part 13 33800 09100 Faucet gasket 14 22800 24608 Faucet rear part 15 10028 01300 Fitting locker 16 22040 00000 Fitting OR 17 00222 02345 Bent 1 4 fitting 18 10028 014...

Page 16: ...erruptor de pared de tipo bipolar con apertura de contactos de 3 mm por lo menos No utilizar cordones conectores para enchufar el aparato al suministro de corriente el ctrica 7 El distribuidor no sale...

Page 17: ...mezcladores seguir n funcionando 5 1 DESCRIPCION DE LOS MANDOS El distribuidor est provisto de un interruptor general y de un interruptor para la luz Cada uno de los contenedores est provisto de un i...

Page 18: ...o fuera posible y los productos permanecieran en los contenedores con el distribuidor parado es conveniente una hora antes de apagar el aparato llevar los interruptores mezcladores y refrigeraci n en...

Page 19: ...aporador el rascador exterior ver figura 7 y despu s el rascador interior Remover frequentemente la guarnici n posterior apretandola hasta que nose pierda l efecto ventosa ver figura 8 figura 7 figura...

Page 20: ...gienizar espec fico preparar una soluci n de agua e hipoclorito de sodio lej a uso alimenticio en la proporci n de 1 cucharadita por cada 2 litros de agua 3 Colocar en la soluci n todas las partes a h...

Page 21: ...ectuada si es necesario solamente como una ulterior prevenci n adicional a la higienizaci n del aparato desmontado descrito anteriormente pero no debe sustituir jam s a la efectuada con el aparato des...

Page 22: ...iginales del fabricante 4 Para prevenir da os al distribuidor las partes de pl stico deben ser lubricadas solamente con la grasa suministrada por el fabricante u otra grasa compatible con policarbonat...

Page 23: ...tador Este es un contador que muestra las 24 horas AM y PM 2 programar el contador de descongelaci n presionando las lenguetas indicadas con la letra C que corresponden a las horas prefijadas para la...

Page 24: ...ricamente a los polos 1 y 2 de la MORSETTIERA No usar los polos 1 y 2 si no viene utilizada alguna electrovalvula de seguridad para el agua Si en el sistema de alimentaci n est n instalados los sensor...

Page 25: ...aciada siguiendo los siguientes pasos 1 Usar un recipiente limpio para cada uno de los siguentes puntos a Recipiente para limpieza rellenar con agua potable caliente 50 60 C b Recipiente por higenizac...

Page 26: ...se haya obtenido un sabor satisfactorio Nota la higienizaci n del sistema de recarga automatica debe ser seguido de la limpieza e higienizaci n del distribuidor como viene ilustrado en el manual de in...

Page 27: ...28 03212 OR grifo 12 22800 24607 Lado anterior grifo 13 33800 09100 Goma del grifo 14 22800 24608 Lado posterior grifo 15 10028 01300 Metal de fijaci n 16 22040 00000 OR conexi n 17 00222 02345 Tubo c...

Page 28: ...SPARE PARTS LIST NHT UL AF B L A C K 2442_49 V 1 2 07C29...

Page 29: ...rear cover Tapa posterior nero 15 22800 16404 Black power switch box Panel para interruptor general 45 22800 00204 NHT 1P 2 3 UL black panel for defrost timer Panel para contador de descongelaci n ner...

Page 30: ...ranaje 24 10028 03204 Bushing Buje 5 10028 03200 Rotor spacer Distancial del rotor 14 10028 03203 3 3 mm spacer Distancial 3 3 mm 25 10028 03205 Washer Arandela 6 33800 03802 Gear box with bushing Caj...

Page 31: ...NHT UL AF BL Ugolini spa 31 NOTES...

Page 32: ...CECILWARE CORPORATION 43 05 20th Avenue Long Island City N Y 11105 Tel 800 935 2211 Fax 718 932 7860 Email cecilware aol com www cecilware com 2442_49 R1 5 07D11...

Reviews: