 9  REPAIR AND MAINTENANCE 

Any  maintenance  operation  must  be  carried  out  by 
qualified personnel in compliance with standard  CEI 

26-29 (IEC 60974-4).

9.1  POWER SOURCE AND TORCH MAINTENANCE

A proper maintenance both of the power source and the 
torch, ensures an optimal performance and lengthen the 
life of all its components, including consumables. There-
fore, we recommend to perform the operations listed in 
the table below.
If, during an inspection, a highly worn component part
is found or one that is not working properly, contact the
CEBORA assistance service.

PERIOD

MAINTENANCE OPERATIONS

Daily

• Check the correct pressure of 
the feed gas.

Weekly

• Check the correct operating of 
the generator fan;
• Clean torch threads and check 

that there are no signs of corro-
sion or electrical discharge

Monthly

• Check the torch wire with re-
spect to cracking, abrasions or 
losses;
• Check the power cord of the unit 

about cracks or abrasions.

Every six months

• Clean the air filter every six 

months, making sure that in the 
tray E there is no trace of con-
densation;

• Replace the the torch O-ring, 

ordering art.2002 kit for CP70C 
torch.

For maintenance of the inner parts of the power source, 

request the assistance of qualified personnel

. In par-

ticular, it is recommended to periodically perform the fol-
lowing operations.

• Clean the inside with compressed air (clean, dry and oil 
free) to eliminate dust buildup. If possible, use a vacuum 
cleaner;
• In particular, provide to clean  with compressed air the 
IGBT module radiators and the diode assembly, directing 
the air jet on them;
• Check that the electrical connections are tight and free 
of overheating;
• Check the internal pneumatic circuit with regard to 
cracks or leaks

.

Also check periodically the grounding system.

9.2  PRECAUTIONS AFTER REPAIRS.

After making repairs, take care to organize the wiring so 
that there is secure insulation between the primary and 
secondary sides of the machine. 
Do not allow the wires or the gas pipes to come into con-
tact with moving parts or those that heat up during op-
eration.
Reassemble all clamps as they were on the original ma-
chine, to prevent a connection from occurring between 
the primary and secondary circuits should a wire acci-
dentally break or be disconnected.
Also mount the screws with geared washers as on the 
original machine.

Summary of Contents for CP 70C Series

Page 1: ...ato Spare parts and wiring diagrams see Annex Schaltpl ne und Ersatzteilliste Siehe Anlage Sch mas lectriques et liste des pi ces de rechange Cf Annexe Esquemas el ctricos lista recambios Ver Anexo Es...

Page 2: ...ANTORCHAS PARA EL CORTE POR PLASMA PT O USO DE CONSUM VEIS N O ORIGINAIS CEBORA ANULA AUTOMATICAMENTE QUALQUER GARANTIA E OU RESPONSABILIDADE DO FABRICANTE NOS GERADORES E MA ARICOS DE CORTE COM PLAS...

Page 3: ...ne o in presenza di polveri gas o vapori esplosivi Maneggiare con cura le bombole ed i regolatori di pressione utilizzati nelle operazioni di taglio COMPATIBILIT ELETTROMAGNETICA Questo apparecchio co...

Page 4: ...o di erogare una corrente max di 50 A al 40 di fattore di utilizzo Sono disponibili differenti set di consumabili in funzione della tipologia di lavoro calibrati e testati per ottenere la massima qual...

Page 5: ...5 Fig 1 Fig 1 A B H G K J N D E M P O S R Q C Z F Fig 1 A 286 590 406...

Page 6: ...cia CP70C ART 326 IEC 60974 1 Fattore di servizio X 40 60 100 Corrente di taglio convenzionale I2 50 A 42 A 33 A Tensione convenzionale di carico U2 100 V 97 V 93 V Tensione nominale a vuoto Uo 250 V...

Page 7: ...ndicate le specifiche dei gas usati con relativa purezza e condizioni di lavoro GAS USATI TITOLO PRESSIONE MAX DI INGRESSO PORTATA Aria Pulita secca e senza olio come da normativa ISO 8573 1 2010 Clas...

Page 8: ...rtura del flusso del gas di alimenta zione poich l arco non si acceso il gas esce dalla torcia per circa 5 secondi in tale condizione regolare la pressione agendo sul la manopola D al valore indicato...

Page 9: ...ochi secondi Data la forte emissione di radiazioni infrarosse e ultravio lette durante questo procedimento si consiglia una pro tezione molto accurata dell operatore e delle persone che si trovano nel...

Page 10: ...te l accensione Led P acceso lampeggiante 5 lampeggi pausa 2 s Contattare il Servizio Assistenza CEBORA Errore torcia Led P acceso lampeggiante 7 lampeggi pausa 2 s Contattare il Servizio Assistenza C...

Page 11: ...ia rispon dente al lavoro scelto la direzione di taglio in funzione della figura da ottene re sia corretta Ricordare che il lato migliore di un taglio sempre quello destro rispetto alla direzione di m...

Page 12: ...ella torcia ordinando il kit art 2002 per torcia CP 70C Per una manutenzione delle parti interne del generato re richiedere l intervento di personale qualificato In particolare si consiglia di eseguir...

Page 13: ...de torch lead and work cables If the electrode torch lead cable is on your right side the work cable should also be on your right side Connect the work cable to the workpiece as close as possible to t...

Page 14: ...ly protect their face 5 1 Wear hat and safety glasses Use ear protection and button shirt collar Use welding helmet with correct shade of filter Wear complete body protection 6 Become trained and read...

Page 15: ...15 Fig 1 Fig 1 A B H G K J N D E M P O S R Q C Z F Fig 1 A 286 590 406...

Page 16: ...data measured in real cutting operation conditions with CP162C CP70C torch IEC 60974 1 Duty Cycle X 40 60 100 Conventional cutting current I2 50 A 42 A 33 A Conventional load voltage U2 100 V 97 V 93...

Page 17: ...ew the protection K onto the panel 3 3 START UP Only skilled personnel should install the machine All connections must be carried out according to current regulations and in full observance of safety...

Page 18: ...lot arc lit unnecessarily in the air this will increase consumption of the electrode diffuser and nozzle Connect the ground cable clamp to the workpiece and make sure that the clamp and the workpiece...

Page 19: ...ozzle C must be re placed when the central hole is damaged or wider than that of a new part Delays in replacing the electrode or nozzle will cause the parts to overheat and jeopardize the life span of...

Page 20: ...t closed during striking LED P On flashing 5 blinks 2 sec pause Contact the CEBORA Service Department Torch error LED P On flashing 7 blinks 2 sec pause Contact the CEBORA Service Department START but...

Page 21: ...peed dross Cutting speed too low Adjust speed Cutting speed too high Reduce cutting current Stand off too low Raise stand off Presence of high speed dross Cutting speed too high Adjust speed Cutting s...

Page 22: ...lace the the torch O ring ordering art 2002 kit for CP70C torch For maintenance of the inner parts of the power source request the assistance of qualified personnel In par ticular it is recommended to...

Page 23: ...e de masa a la pieza en tratamiento lo m s cerca posible a la zona de soldadura o de corte No trabajar cerca del generador EXPLOSIONES No cortar en proximidad de recipientes a pre si n o en presencia...

Page 24: ...a o de ejecutar cualquiera operaci n con la misma 7 No quitar ni cubrir las etiquetas de advertencia 2 DESCRIPCI N GENERAL Este aparato es un generador de corriente continua cons tante proyectado para...

Page 25: ...25 Fig 1 Fig 1 A B H G K J N D E M P O S R Q C Z F Fig 1 A 286 590 406...

Page 26: ...de corte con la antorcha CP162C CP70C ART 326 IEC 60974 1 Factor de servicio X 40 60 100 Corriente de corte convencional I2 50 A 42 A 33 A Tensi n convencional de carga U2 100 V 97 V 93 V Tensi n nom...

Page 27: ...A continuaci n se indican las especificaciones de los ga ses utilizados con respectiva pureza y condiciones de trabajo Gases utilizados T tulo Presi n m xima de entrada Caudal Aire Limpio seco y sin a...

Page 28: ...e alimentaci n dado que el arco no se ha encendido el gas sale de la antorcha durante unos 5 segundos en tal situaci n operar con el mando D para regular la presi n seg n el valor indicado en la placa...

Page 29: ...ruir la tobera en pocos segundos Dada la fuerte emisi n de radiaciones infrarrojas y ultra violetas que tiene lugar durante la ejecuci n de este pro cedimiento se aconseja proteger muy cuidadosamente...

Page 30: ...cendido Led P encendido parpadeante 5 parpadeos pausa 2 s Contactar con el Servicio de Asistencia CEBORA Error antorcha Led P encendido parpadeante 7 parpadeos pausa 2 s Contactar con el Servicio de A...

Page 31: ...de penetraci n en especial tratar de quitar la acumulaci n de material fun dido en torno al agujero de inicio del corte a fin de evitar fen menos de doble arco cuando la antorcha vuelve a pasar por el...

Page 32: ...tes inter nos del generador se debe solicitar la intervenci n de personal cualificado En particular se aconseja ejecutar peri dicamente las operaciones que a continuaci n se indican Limpiar la parte i...

Reviews: