![Cebora CP 70C Series Instruction Manual Download Page 16](http://html1.mh-extra.com/html/cebora/cp-70c-series/cp-70c-series_instruction-manual_2577464016.webp)
16
2.2 EXPLANATION OF THE TECHNICAL SPECIFICA-
TIONS LISTED ON THE MACHINE PLATE.
The equipment is manufactured according to these
international standards:IEC 60974-1, IEC 60974-7, IEC
60974-10 Cl. A, IEC 61000-3-11, IEC 61000-3-12
* Machine data measured according to standard IEC60974-1
** Machine data measured in real cutting operation conditions with CP162C/CP70C torch
IEC 60974-1 *
Duty Cycle (X)
40 %
60 %
100 %
Conventional cutting current (I2)
50 A
42 A
33 A
Conventional load voltage (U2)
100 V
97 V
93 V
Rated no load voltage (Uo)
250
Rated supply voltage (U1)
1 ~ 50/60 Hz
250 V
Rated maximum supplied current (I1max)
26 A
Maximum effective supply current (I1eff)
16 A
CEBORA
CP 70C**
Cutting current (I2)
50 A
Output voltage (U2)
135 V
Maximum supply current (I1max)
32 A
Housing protection degree
IP23S