![CEA MATRIX 2200 AC/DC Operator'S Manual Download Page 34](http://html1.mh-extra.com/html/cea/matrix-2200-ac-dc/matrix-2200-ac-dc_operators-manual_2577246034.webp)
12
2D) SYN PULSE
TIG pulse welding with synergic setting of parameters.
WARNING: This can only be programmed when the TIG DC with
HF ignition or TIG DC with “Lift” type ignition weld-
ing processes are used.
Press the PULSE key (T5) until the requited pulsation
is active.
Press the WELDING PARAMETERS SELECTION Key
(T10) a number of times to set the following (in addi-
tion to the WELDING PARAMETERS defined as be-
ing “BASIC”):
L20
L21
L23
T10
L20
BASE CURRENT I
b
2200 AC/DC
3000 AC/DC
25 ÷ 220 A
25 ÷ 300 A
This function, which is good for less skilled operators, makes it
possible to change the pulsation parameter (Peak current
I
p
) and
the other values for the corresponding pulsation parameters (Base
current
I
b
- Pulsation frequency
f
) vary automatically.
To exit the setting phase, hold the WELDING PARAMETERS SE-
LECTION key (T10) down for about
1 second
.
3 - WELDING PARAMETERS with PULSE mode and
CYCLE welding mode active (CYCLE LED on)
When this welding mode is active it is possible to work at
2
differ-
ent pulse current levels (
I
1
and
I
2
). To do so you must also set (not
only pulse parameters
I
b
,
I
p
, and
f
), but also the 2
nd
level PEAK
current (
I
2p
). The other 2
nd
level pulse parameters (BASIC CUR-
RENT
I
2b
and FREQUENCY
f
) are achieved synergically. The
FREQUENCY remains constant while the 2
nd
level BASIC CUR-
RENT
I
2b
is proportional to the ratio between the 1
st
level currents.
3A - SLOW PULSE + CYCLE
Press the PULSE key (T5) until the requited
pulsation is active (SLOW LED on).
Press the WELDING MODE SELECTION key
(T9) until the CYCLE welding mode is active
(CYCLE LED on).
Press the WELDING PARAMETERS SELEC-
TION Key (T10) a number of times to set the
following (in addition to the WELDING PARAM-
ETERS defined as being “BASIC”):
T10
L11 L19 L20
L21
L15
L14
PULSE
SYN
FAST
SLOW
T5
PULSE
SYN
FAST
SLOW
T5
T9
L11
-
L21
1
st
LEVEL PEAK CURRENT I
1p
2200 AC/DC
3000 AC/DC
TIG DC
5 ÷ 220 A
5 ÷ 300 A
TIG AC
DYNAMIC TIG
SPEED TIG
COLD TIG
SOFT TIG
5 ÷ 220 A
5 ÷ 220 A
16 ÷ 127 A
16 ÷ 156 A
5 ÷ 300 A
5 ÷ 300 A
5 ÷ 173 A
5 ÷ 212 A
L19
2
nd
LEVEL PEAK CURRENT I
2p
2200 AC/DC
3000 AC/DC
TIG DC
5 ÷ 220 A
5 ÷ 300 A
TIG AC
DYNAMIC TIG
SPEED TIG
COLD TIG
SOFT TIG
5 ÷ 220 A
5 ÷ 220 A
16 ÷ 127 A
16 ÷ 156 A
5 ÷ 300 A
5 ÷ 300 A
5 ÷ 173 A
5 ÷ 212 A
L20
1
st
LEVEL BASE CURRENT I
1b
2200 AC/DC
3000 AC/DC
TIG DC
5 ÷ 220 A
5 ÷ 300 A
TIG AC
DYNAMIC TIG
SPEED TIG
COLD TIG
SOFT TIG
5 ÷ 220 A
5 ÷ 220 A
16 ÷ 127 A
16 ÷ 156 A
5 ÷ 300 A
5 ÷ 300 A
5 ÷ 173 A
5 ÷ 212 A
L15
PEAK current duration T
p
2200 AC/DC - 3000 AC/DC
TIG DC
0,01 ÷ 0,99 sec
TIG AC
0,10 ÷ 0,99 sec
L14
BASE current duration T
b
2200 AC/DC - 3000 AC/DC
TIG DC
0,01 ÷ 0,99 sec
TIG AC
0,10 ÷ 0,99 sec
To exit the setting phase, hold the WELDING PARAMETERS SE-
LECTION key (T10) down for about
1 second
.
3B - FAST PULSE + CYCLE
Press the PULSE key (T5) until the requited
pulsation is active (FAST LED on).
Press the WELDING MODE SELECTION key
(T9) until the CYCLE welding mode is active
(CYCLE LED on).
Press the WELDING PARAMETERS SELEC-
TION Key (T10) a number of times to set the
following (in addition to the WELDING PARAM-
ETERS defined as being “BASIC”):
L11 L19 L20
L21
L23
T10
PULSE
SYN
FAST
SLOW
T5
T9
Summary of Contents for MATRIX 2200 AC/DC
Page 10: ...10 Wiring diagram MATRIX 2200 AC DC...
Page 11: ...11 2101WA31...
Page 12: ...12 Wiring diagram MATRIX 3000 AC DC AC DC R 3000 MTA 30...
Page 13: ...13 2101WB09...