4
■
PULSE
When using one of the 3 TIG welding processes, it makes it pos-
sible to set one of the
4
pulsation modes available on the welding
machine, using the relevant button:
L27
SYN PULSE
L28
FAST PULSE
L28
ULTRA FAST PULSE
L29
SLOW PULSE
PULSE
SYN
FAST
SLOW
L27
L28
L29
L27
Synergic pulsations (SYN PULSE)
WARNING:
LED
L27
switched on and steady.
This can only be programmed when the
TIG DC with HF ignition
or
TIG DC with “Lift” type ignition welding processes are used.
L28
Fast pulsations (FAST PULSE)
WARNING:
LED
L28
switched on and steady.
This can only be programmed when the
TIG DC with HF ignition
or
TIG DC with “Lift” type ignition welding processes are used.
L28
Ultra fast pulsations (ULTRA FAST PULSE)
WARNING:
LED
L28
switched on and flashing.
Attivabile solo con i processi di saldatura
TIG DC con innesco HF
o
TIG DC con innesco tipo “Lift”.
L29
Slow pulsations (SLOW PULSE)
WARNING:
LED
L29
switched on and steady.
This can only be programmed when the
3 TIG welding process-
es are used.
WARNING: The operator can decide to TIG weld without using
any pulsation mode. If this is the case, the
4 LEDs are switched off.
■
WELDING PARAMETERS
Each time the button is pushed, the welding machine selects the
next function according to the machine configuration, the welding
process, the welding mode, etc...
1A - STANDARD CONFIGURATION
Electrode welding (MMA)
When using the electrode welding process, this allows you to select
the following welding parameters, based on which LED is flashing:
L9
HOT START
L10
ARC FORCE
L11
PRINCIPAL welding CURRENT I
1
L9
L10
L11
1B - STANDARD CONFIGURATION
TIG welding
When one of the
3
TIG welding processes available on the welding
machine is activated, this allows you to select the following weld-
ing parameters, based on which LED is flashing:
L12
PRE-GAS duration
L13
SLOPE UP duration
L14
BASE current duration T
b
WARNING: This can only be programmed when SLOW pulsa-
tion is activated.
L15
PEAK current duration T
p
WARNING: This can only be programmed when SLOW pulsa-
tion is activated.
L16
SLOPE DOWN duration
L17
POST-GAS duration
L18
INITIAL welding CURRENT
L11
PRINCIPAL welding CURRENT I
1
L19
CYCLE CURRENT I
2
WARNING: This can only be programmed when the CYCLE weld-
ing mode is active.
L20
BASE CURRENT I
b
WARNING: This can only be programmed when at lease one pul-
sation mode is activated.
L21
PEAK CURRENT I
p
WARNING: This can only be programmed when at least one pul-
sation mode is activated.
L22
FINAL welding CURRENT
L23
PULSATION FREQUENCY f
WARNING: NOT programmable when SLOW pulsation mode is
active.
L18 L11 L19 L20
L21 L22
L17
L16
L15
L23
L14
L13
L12
2 - SPECIAL CONFIGURATION
(only for expert welders)
TIG welding
For this configuration, in addition to the parameters already de-
fined for the STANDARD configuration, you can also set the fol-
lowing parameters:
L9
IGNITION CURRENT
WARNING: This can only be programmed when the TIG AC with
HF ignition or TIG DC with HF ignition welding processes are
used.
L9
IGNITION TIME duration
WARNING: Only programmable when the TIG AC with HF igni-
tion welding process is activated.
L18
INITIAL welding CURRENT
WARNING: This can only be programmed when the TIG AC with
HF ignition or TIG DC with HF ignition welding processes and
the
2 STROKES welding mode are used.
L22
FINAL welding CURRENT
WARNING: This can only be programmed when the TIG AC with
HF ignition or TIG DC with HF ignition welding processes and
the
2 STROKES welding mode are used.
L9
L18
L22
WARNING: This special parameter is only to be activated by
qualified personnel, or those trained by technicians.