background image

9

cdvigroup.com

FR

BO600RP - BO600RH

Bandeau architectural

  MANUEL D’INSTALLATION

Détail produits

2] RAPPELS ET RECOMMANDATIONS

Profi l

poignée avec 

bouchons

Profi l

cache-vis

Capot pour 

support 

mural

Profi l

support 

mural

Bouchons

casquette

Poignée

Kit

visserie

Notice

BO600RP 2500 mm

1

1

1

1

2

1

1

1

BO600RPSTD 2190 mm

1

1

1

1

2

1

1

1

BO600RH 925 mm

1

1

1

1

2

-

1

1

BO600RP 2500 MM

BO600RPSTD 2190 MM

BO600RH 925 MM

Ventouse(s) 300 Kg

avec Contreplaque(s)

2

2

2

Support mural

avec Capot

1

1

1

Poignée bandeau

avec Cache vis

1

1

1

Bouchons Poignée bandeau

2

2

2

Bouchons Support mural

2

2

2

Possibilité de teinte

RAL (option)

-

Coupe sur-mesure (option)

-

3 ou 4 ventouses (option)

-

-

Signal (option)

-

3] ÉLÉMENTS FOURNIS

Conformité NFS 61-937

Ce produit remplit les exigences de la norme NFS 

61-937 uniquement sous une tension d’alimentation 

continue de 24V ou 48V fournie par une source TBTS. 

Seul le montage vertical est admis. Se référer au 

paragraphe 7] pour les schémas de raccordement.

Alimentations préconisées

Le bandeau est conçu pour des ventouses ayant une 

force de retenue chacune de 400 Kg, alimentées 

sous 12 V DC ou 24 V DC. Prévoir une alimentation 

suivant le branchement choisi. L’arrivée de courant 

se fait coté fi xe ou semi-fi xe à l’aide d’un fl exible si 

nécessaire. Il existe 2 alimentations adaptées pour le  

BO600RH (avec 2 ventouses) : BS602 ou ARD2/12 

en 12 V DC et ADC24, AS6 ou BS24 en 24 V DC

Câblage

Prévoir  du  fi l  9/10  souple.  Nous  préconisons  une

distance maximun de 10 mètres, entre la ventouse 

et son alimentation. Si cette distance est supérieure, 

prévoir le câble nécessaire à l’installation.

Conseils d’utilisation

Le bandeau s’installe sur des portes en tirant

et  affl eurantes  à  un  ou  deux  vantaux  (service/

semi-fi xe).  Il  se  pose  sur  des  portes  parfaitement 

alignées, dans le cas contraire, il faut prévoir une

cale (Réf : REO). Vous pouvez également renforcer votre 

porte avec le profi l renfort (Ref: PRP800) et cacher votre 

installation électrique avec le passe-câble (Ref: ALMA).

Rappel

Les  ventouses  sont  déjà  montées  sur  le  support

mural. La poignée bandeau est équipée en série des 

contreplaques et des bouchons à chaque extrémité.

Poignée (BO600RP)

Vous devez impérativement fi xer la poignée plastique 

avec les deux vis dédiées fournies avec le produit.

Summary of Contents for BO600RH

Page 1: ...ice cdvigroup com BO600RH ENGLISH ENGLISH EN FRANCAIS FRANCAIS FR P300RP BO600RP BO600RP BO600RH P300RP P600RP Vertical Horizontal retrofit housing Bandeau architectural vertical horizontal Retrofit handle Poignées ventouse ...

Page 2: ...Dimensions L x W x D BO600RH 925 x 105 x 62mm BO600RPSTD 2190 x 105 x 63mm BO600RP 2500 x 105 x 63mm Magnet housing for frame mount Armature housing with end caps for door mount Input voltage 12 24 48V dc Consumption 12V dc 500mA per magnet 24V dc 250mA per magnet 48V dc 250mA for both magnets CE Certification WEEE 20 C to 70 C Thank you for buying our products and for the confidence you placed in o...

Page 3: ...oss section of the cable to compensate General Advice The 2 parts of the architectural housing are designed to be surface mounted on the door and frame where they should be parallel when the door is closed If there is a rebate then it will be necessary to pack out the lower part to be parallel to the other Aluminium rail spacer Ref REO You can also use the PRP800 Reinforcement section or ALMA Alum...

Page 4: ...r into place fix the end caps and secure with the screws provided To finalise the assembly tighten all fixings and protect the handle fixing section by fitting the cover and end caps With the door closed position the architectural handle onto the edge of the opening leaf of the door ensuring the handle covers the box section Mark the vertical and horizontal holes drill as required then temporarily fix t...

Page 5: ...e assembly tighten all fixings and protect the handle fixing section by fitting the cover and end caps 1 Cut the top cover unit into 2 pieces Double check the length of each section of top cover before final cutting Take into account the plastic handle 215MM Ensure the plastic handle is at optimum position for users then make the final cuts to the covers Insert the end caps and secure Insert the plasti...

Page 6: ...r 24Vdc positive 12Vdc or 24Vdc negative NC Contact Normally Closed COM Common NO Contact Normally Open Voltage 12Vdc or 24Vdc Place the jumpers to select 12Vdc or 24Vdc supply to your magnetic locks 5 WAY TERMINAL STRIP NON MONITORED VERSION 12Vdc or 24Vdc positive 12Vdc or 24Vdc negative Voltage 12Vdc or 24Vdc Place the jumpers to select 12Vdc or 24Vdc supply to your magnetic locks 5 Way Termina...

Page 7: ...7 cdvigroup com 6 NOTES EN BO600RP BO600RH Vertical Horizontal retrofit housing INSTALLATION MANUAL ...

Page 8: ...sions L x l x P BO600RH 925 x 105 x 62 mm BO600RPSTD 2190 x 105 x 63 mm BO600RP 2500 x 105 x 63 mm Poteau technique sur le dormant prévu pour l installation des ventouses Poignée bandeau sur l ouvrant pour l installation des contre plaques Bouchons ABS pour extrémités bandeaux et poteau technique Alimentation 12 24 48 V DC Consommation 12 V DC 500 mA par ventouses 24 V DC 250 mA par ventouses 48 V...

Page 9: ...ur des ventouses ayant une force de retenue chacune de 400 Kg alimentées sous 12 V DC ou 24 V DC Prévoir une alimentation suivant le branchement choisi L arrivée de courant se fait coté fixe ou semi fixe à l aide d un flexible si nécessaire Il existe 2 alimentations adaptées pour le BO600RH avec 2 ventouses BS602 ou ARD2 12 en 12 V DC et ADC24 AS6 ou BS24 en 24 V DC Câblage Prévoir du fil 9 10 souple ...

Page 10: ...gement Pour le bandeau même procédure installez le cache vis dans sa charnière et emboitez le dans son logement Positionnez la poignée bandeau munie de ses contreplaques sur l ouvrant Prenez les marques dans les trous oblongs horizontaux et verticaux pour fixer la poignée bandeau Percer la surface de la porte au niveau des marques réalisées Placez et vissez provisoirement la poignée afin de laisser ...

Page 11: ...ment 1 Coupez le cache vis en deux parties distinctes de manière à pouvoir insérer la poignée encombrement environ 250 mm Vérifiez que la poignée est située à une hauteur accaptable du sol pour en faciliter l usage Présenter les cache vis et les clipser dans le profilé puis placez la poignée Pour garantir la bonne tenue de la poignée dans le temps il est impératif de fixer la poignée avec les deux vi...

Page 12: ... 12 V ou 24 V DC 12 V DC 12 V DC 12 V DC 24 V DC 24 V DC 24 V DC BORNIER 5 POINTS VENTOUSE Alimentation 12 V ou 24 V DC Alimentation 12 V ou 24V DC NC Contact Normalement Fermé COM Commun NO Contact Normalement Ouvert Alimentation 12 V DC ou 24 V DC En fonc tion du placement des cavaliers vous alimentez votre ventouse en 12 V DC ou en 24 V DC Alimentation 12 V ou 24 V DC Alimentation 12 V ou 24V D...

Page 13: ...ntation 48 V DC Ventouses raccordées en série BBG ou BRC GAMME BO600RP Ventouse 2 x 300 KG 13 cdvigroup com FR BO600RP BO600RH Bandeau architectural MANUEL D INSTALLATION Montage N 1 Alimentation 24 V DC VENTOUSE N 1 VENTOUSE N 2 Alimentation 24 V DC Ventouses raccordées en parallèle ARD212 GAMME BO600RP Ventouse 2 x 300 KG Alimentation 24 V DC BBG ou BRC 8 NOTES ...

Page 14: ...PORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI SUISSE Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 62414516 Fax 86 0 10 62414519 CDVI IBÉRICA SPAIN PORTUGAL Phone 34 0 935 390 966 Fax 34 0 935 390 970 CDVI ITALI...