6
cdvigroup.com
Example N°2: Access C Exit Button
ARD212
Access
Control
Unit
5] WIRING
Example N°1: Exit button only (VHLD timer optional)
Voltage 12Vdc
or 24Vdc
Exit
Button
Access
Control
Unit
Example N°3: Access C Exit Button
Input voltage:
48 V DC*
MAGNETIC LOCK
N°1
MAGNETIC LOCK
N°1
MAGNETIC LOCK
N°2
MAGNETIC LOCK
N°1
MAGNETIC LOCK
N°2
MAGNETIC LOCK
N°2
24 V DC
Input voltage: 48 VDC.
Magnetic locks connected in series.
Exit Button
ARD212
BO600RP RANGE
2 x 300KG magnetic locks
BO600RP RANGE
2 x 300KG magnetic locks
BO600RP RANGE
2 x 300KG magnetic locks
Voltage 12Vdc
or 24Vdc
12Vdc
12Vdc
12Vdc
24Vdc
24Vdc
24Vdc
5-WAY TERMINAL STRIP
MONITORED VERSION
+
12Vdc or 24Vdc positive *
-
12Vdc or 24Vdc negative *
NC Contact «Normally Closed»
COM Common
NO Contact «Normally Open»
* Voltage: 12Vdc or 24Vdc.
Place the « jumpers » to select 12Vdc
or 24Vdc supply to your magnetic locks.
5-WAY TERMINAL STRIP
NON MONITORED VERSION
+ 12Vdc or 24Vdc positive *
- 12Vdc or 24Vdc negative *
* Voltage: 12Vdc or 24Vdc.
Place the « jumpers » to select 12Vdc or 24Vdc
supply to your magnetic locks
5-Way Terminal Strip
– non monitored version
+ 12Vdc or 24Vdc positive *
- 12Vdc or 24Vdc negative *
* Voltage: 12Vdc or 24Vdc.
Place the « jumpers » to select
12Vdc or 24Vdc supply to your
magnetic locks
Adjustable timer
(0 to 20 seconds)
TIME RELAY FOR MAGNETIC LOCKS (REF: TPV)
Important: When using a timer
in circuit, please make note of the voltage
used and ensure the timer can operate
at the same voltage (example
shows TPV).
Exit
Button
EN
BO600RP - BO600RH
Vertical & Horizontal retrofi t housing
INSTALLATION MANUAL