Power Considerations

The handle is designed to house electromagnets

with a holding force of 300Kg each. These units can be 

supplied by either 12Vdc or 24Vdc depending upon your 

preferred choice (48Vdc supplied on special request). 

The current required depends on the amount of 

electromagnetic locks, and the voltage chosen – please 

see Technical Specifi cation, and ensure you have allocated 

suffi cient  power  to  BO600RH  (2500mm  housing  with  2 

magnetic locks) would require: PSU12/2 or ARD2/12 at 

12Vdc PSU24/1 or ARD24 at 24Vdc.

Information

The electromagnets are pre-fi tted within the lock section. 

The armature plates are pre-fi tted within the architectural 

handle. Both sections are supplied with end caps.

Wiring

Plan your cable routes before commencing installation. We 

recommend a maximum distance of 10m from the power 

supply to the electromagnetic locks  (to prevent volt 

drop). If the distance is greater, then make sure you have 

increased the cross section of the cable to compensate.
General Advice

The 2 parts of the architectural housing are designed to 

be surface mounted on the door and frame, where they 

should be parallel when the door is closed. If there is a 

rebate, then it will be necessary to pack out the lower 

part to be parallel to the other (Aluminium rail spacer, 

Ref:  REO). You can also use the PRP800 (Reinforcement 

section) or ALMA (Aluminium Cable tray) to reinforce the 

housing mounting.
Handle (BO600RP)

You must secure the handle with the 2 screws which 

comes with the retrofi t housing.

3

cdvigroup.com

EN

BO600RP - BO600RH

Vertical & Horizontal retrofi t housing

  INSTALLATION MANUAL

BO600RP

2500MM

BO600RPSTD 

2190MM

BO600RP

925 MM

Number of 300Kg magnets

2

2

2

Lock section with cover

1

1

1

Architectural handle  with fi xing cover

1

1

1

End caps for handle

2

2

2

End caps for lock section

2

2

2

RAL colour (option)

-

Cut to size (option)

-

3 or 4 magnetic locks (option)

-

-

Monitored (option)

-

3] PACKAGE CONTENTS

Profi led 

handle

with end 

caps

Profi led 

handle 

fi xings

cover

Box

section 

back-plate

Box

section 

cover

End caps

Handle

screw kit

Manual

BO600RP

2500 mm

1

1

1

1

2

1

1

1

BO600RPSTD

2190 mm

1

1

1

1

2

1

1

1

BO600RH 925 

mm

1

1

1

1

2

-

1

1

Summary of Contents for BO600RH

Page 1: ...ice cdvigroup com BO600RH ENGLISH ENGLISH EN FRANCAIS FRANCAIS FR P300RP BO600RP BO600RP BO600RH P300RP P600RP Vertical Horizontal retrofit housing Bandeau architectural vertical horizontal Retrofit handle Poignées ventouse ...

Page 2: ...Dimensions L x W x D BO600RH 925 x 105 x 62mm BO600RPSTD 2190 x 105 x 63mm BO600RP 2500 x 105 x 63mm Magnet housing for frame mount Armature housing with end caps for door mount Input voltage 12 24 48V dc Consumption 12V dc 500mA per magnet 24V dc 250mA per magnet 48V dc 250mA for both magnets CE Certification WEEE 20 C to 70 C Thank you for buying our products and for the confidence you placed in o...

Page 3: ...oss section of the cable to compensate General Advice The 2 parts of the architectural housing are designed to be surface mounted on the door and frame where they should be parallel when the door is closed If there is a rebate then it will be necessary to pack out the lower part to be parallel to the other Aluminium rail spacer Ref REO You can also use the PRP800 Reinforcement section or ALMA Alum...

Page 4: ...r into place fix the end caps and secure with the screws provided To finalise the assembly tighten all fixings and protect the handle fixing section by fitting the cover and end caps With the door closed position the architectural handle onto the edge of the opening leaf of the door ensuring the handle covers the box section Mark the vertical and horizontal holes drill as required then temporarily fix t...

Page 5: ...e assembly tighten all fixings and protect the handle fixing section by fitting the cover and end caps 1 Cut the top cover unit into 2 pieces Double check the length of each section of top cover before final cutting Take into account the plastic handle 215MM Ensure the plastic handle is at optimum position for users then make the final cuts to the covers Insert the end caps and secure Insert the plasti...

Page 6: ...r 24Vdc positive 12Vdc or 24Vdc negative NC Contact Normally Closed COM Common NO Contact Normally Open Voltage 12Vdc or 24Vdc Place the jumpers to select 12Vdc or 24Vdc supply to your magnetic locks 5 WAY TERMINAL STRIP NON MONITORED VERSION 12Vdc or 24Vdc positive 12Vdc or 24Vdc negative Voltage 12Vdc or 24Vdc Place the jumpers to select 12Vdc or 24Vdc supply to your magnetic locks 5 Way Termina...

Page 7: ...7 cdvigroup com 6 NOTES EN BO600RP BO600RH Vertical Horizontal retrofit housing INSTALLATION MANUAL ...

Page 8: ...sions L x l x P BO600RH 925 x 105 x 62 mm BO600RPSTD 2190 x 105 x 63 mm BO600RP 2500 x 105 x 63 mm Poteau technique sur le dormant prévu pour l installation des ventouses Poignée bandeau sur l ouvrant pour l installation des contre plaques Bouchons ABS pour extrémités bandeaux et poteau technique Alimentation 12 24 48 V DC Consommation 12 V DC 500 mA par ventouses 24 V DC 250 mA par ventouses 48 V...

Page 9: ...ur des ventouses ayant une force de retenue chacune de 400 Kg alimentées sous 12 V DC ou 24 V DC Prévoir une alimentation suivant le branchement choisi L arrivée de courant se fait coté fixe ou semi fixe à l aide d un flexible si nécessaire Il existe 2 alimentations adaptées pour le BO600RH avec 2 ventouses BS602 ou ARD2 12 en 12 V DC et ADC24 AS6 ou BS24 en 24 V DC Câblage Prévoir du fil 9 10 souple ...

Page 10: ...gement Pour le bandeau même procédure installez le cache vis dans sa charnière et emboitez le dans son logement Positionnez la poignée bandeau munie de ses contreplaques sur l ouvrant Prenez les marques dans les trous oblongs horizontaux et verticaux pour fixer la poignée bandeau Percer la surface de la porte au niveau des marques réalisées Placez et vissez provisoirement la poignée afin de laisser ...

Page 11: ...ment 1 Coupez le cache vis en deux parties distinctes de manière à pouvoir insérer la poignée encombrement environ 250 mm Vérifiez que la poignée est située à une hauteur accaptable du sol pour en faciliter l usage Présenter les cache vis et les clipser dans le profilé puis placez la poignée Pour garantir la bonne tenue de la poignée dans le temps il est impératif de fixer la poignée avec les deux vi...

Page 12: ... 12 V ou 24 V DC 12 V DC 12 V DC 12 V DC 24 V DC 24 V DC 24 V DC BORNIER 5 POINTS VENTOUSE Alimentation 12 V ou 24 V DC Alimentation 12 V ou 24V DC NC Contact Normalement Fermé COM Commun NO Contact Normalement Ouvert Alimentation 12 V DC ou 24 V DC En fonc tion du placement des cavaliers vous alimentez votre ventouse en 12 V DC ou en 24 V DC Alimentation 12 V ou 24 V DC Alimentation 12 V ou 24V D...

Page 13: ...ntation 48 V DC Ventouses raccordées en série BBG ou BRC GAMME BO600RP Ventouse 2 x 300 KG 13 cdvigroup com FR BO600RP BO600RH Bandeau architectural MANUEL D INSTALLATION Montage N 1 Alimentation 24 V DC VENTOUSE N 1 VENTOUSE N 2 Alimentation 24 V DC Ventouses raccordées en parallèle ARD212 GAMME BO600RP Ventouse 2 x 300 KG Alimentation 24 V DC BBG ou BRC 8 NOTES ...

Page 14: ...PORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI SUISSE Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 62414516 Fax 86 0 10 62414519 CDVI IBÉRICA SPAIN PORTUGAL Phone 34 0 935 390 966 Fax 34 0 935 390 970 CDVI ITALI...

Reviews: