If equipment has been altered in any way from original design, the manufacturer does
not accept any liability for injury or warranty.
4.1 Vacuum System (Station/Wayside Only)
4.1.1 Tank Emptying
The vacuum collection tank will need to be emptied
periodically. To do so, open the vacuum service door
located on the right rear sloped roof panel of the unit.
Insert the appropriate key into the lock cylinder and turn
90 degrees clockwise to release the door latch. Open the
door and swing on the hinges fully to rest on the upper
roof panel. Take care in high wind situations that the
door does not blow back closed unexpectedly or personal
injury may occur. Remove the blue pipe plug by turning it
counter clockwise and removing it. The rubber ring
around the plug should also be removed for clear access
into the tank. Take care not to drop the rubber sealing
ring into the tank port.
The tank should be evacuated using a septic pumping rig
or something similar. It is recommended to use a long
extension to the suction hose and to agitate the material
in the tank as it is being removed or prior to removing it.
This prevents clumping to the bottom of the tank and
more complete tank evacuation.