Control with External Signals (Continued) 

To Set ON/OFF Signal in ON/OFF Mode

Specify the ID and the channel, and set ON/OFF signal.

4

@FFL000A8CRLF

@FFO007BCRLF

@FFN0300DDCRLF

To Check the Setting Status

When checking the setting status, send the following command after specify 

the ID and the channel.

@00OF075.S04.L000C0CRLF

@00N0300B1CRLF

@00M004DCRLF

Checking the Unit Status

Specify the ID and send the following command to check the unit status.

@00C0043CRLF

@00O0000AFCRLF

@00N0300B1CRLF

Resetting the Light Intensity and Lighting Mode

To restore the external control setting to default value, send the following 

command after specify the ID.

@00R0052CRLF

@00O004FCRLF

@00N0300B1CRLF

1

Setting the Manual/External Mode Selector to External

Set the Manual/External Mode Selector to EXT to set External Mode. The value set with external control is displayed on the digital window.

* Although it is possible to set the external control setting even the manual/external mode selector is set to manual mode, the setting will not be activated until the 

manual/external mode selector is set to external mode.

Setting Procedures

● Set items       and      when using Continuous Mode.

1

2

Make sure that the main power source is turned ON.

4

● Set items      ,      , and       when using ON/OFF Mode.

1 2

Set items      ,      , and       when using Strobe Mode.

1

3

2

*9) Default setting for trigger logic switch is HIGH =‘1(ON)’ and LOW =‘0(OFF)’. 

*10) There is no received data when timeout error occurs or ID setting of sent data is out of range.

*11) Received command for setting status check (F999.S99.L9)  F999=Light intensity setting (F000 to F255), S99=Lighting mode setting (S00 to S10), L9=ON/OFF setting (L0: Not lit / L1: Lit)

The lowest byte (two characters) of 1DF is taken, 
so the checksum is DF.

The codes of the ASCII characters from the header 
to the ID are added, the lowest byte is converted to 
hexadecimal, and two characters are sent.

40H

30H

31H

46H

31H

32H

@

0

1

F

1

2

30H

30H

0

0

35H

5

1DFH

*8) 

Checksum

Header

Byte 2

Byte 1

Byte 3 Byte 4

Sent command

Channel

ID

Byte 5 Byte 6 Byte 7 Byte 8 Byte 9

Total

Example: Setting the Light Intensity of Channel 2 to 125 for the PD3 with an ID 00

ASCII

(hexadecimal)

Character

*7) 

ID Specification

The Control Units are identified with the ID switch settings. Up to four Units can be connected to one signal line. The EIA-485 communications circuit will be 
terminated inside the Control Unit if the ID switch is set to 00 (left and right pins ON). Always connect a PD3 that has the ID switch set to 00 to the end of the 
connection line. Also make sure that each ID is used only once on the same signal line.

ON OFF

ON

01

00

ON OFF

ON

02

OFF OFF

03

When using more than two products to be connected, please use 

the external control junction cable (optional, sold separately).

First unit

Second units

Third units

EXCB2-E3-3

1
1
1

EXCB2-E3-E3-0.2

---

2
3

ECNR-E3CN4

---

1
1

Fourth units

1

5

2

PD3  ID:00

PD3  ID:01

PD3  ID:02

PD3  ID:03

4 Units max.

Maximum line length: 30 m

Unit with ID 00 is terminated (120 Ω).

Computer 

or PLC

Right Left

Left

ID switch

Set value

Left Right

Right

Left Right

Setting example

Setting example

Setting example

Setting example

Send data

Send data

Send data

Send data

Receive data when OK

Receive data when OK

Receive data when OK

Receive data when OK

Receive data when NG

Receive data when NG

Receive data when NG

Receive data when NG

Setting the Light Intensity

Specify the ID and the channel, and set the light intensity.

2

@02F07500E4CRLF

@02O0051CRLF

@02N0300B3CRLF

Setting example

Send data

Receive data when OK Receive data when NG

Setting the light intensity 

to 75 for L3 of the PD3 that 

has the ID set to 00

(when there is a set value 

 out of range error)

(when there is a set value 

 out of range error)

(when there is a set value 

 out of range error)

(when there is a set value 

 out of range error)

(when there is a set value 

 out of range error)

Setting the Lighting Mode

Specify the ID and channel, and set the lighting mode.

3

@01S0400B8CRLF

@01O0050CRLF

@01N0300B2CRLF

Setting example

Send data

Receive data when OK Receive data when NG

(when there is a set value 

 out of range error)

Setting the lighting mode to Strobe 

Mode at 200 µs for L2 of the PD3 

that has the ID set to 00

(normal)

Checking the status of the 

PD3 that has the ID set to 00

Restoring all channels back 

to default values for the PD3 

that has the ID set to 00

To turn all light units 

OFF of the PD3 

that has the ID set to 00

To check the setting status 

for L1 of the PD3 that 

has the ID set to 00.

(If Intensity=75, Strobe mode=200μs, 

Light unit=OFF)

77

Number of 

Light Units

Cables

Summary of Contents for PD3-5024-4-SI

Page 1: ...esult in electric shock Make sure that the product is free of moisture or any liquid Doing so may result in fire or electric shock Before connecting or disconnecting cables make sure that the power so...

Page 2: ...lets or fan exhaust outlets Insufficient ventilation may cause heat to accumulate inside the product and result in a fire Mounting the Unit to DIN Rail Mounting to DIN Rail Hook the tab on the upper p...

Page 3: ...urned OFF with manual or external control To use ON OFF Mode or Strobe Mode connect the external trigger input cable to the external trigger input connector Insert the connector to the Light Unit all...

Page 4: ...nal control Variable current control Per connector 3 9 W max 700mA max Depends on the light intensity of the Light Unit Only connected Light Units can be selected Detected at any time 3 s 10 5 6 5 6 5...

Page 5: ...lash the strobe turn the setting switch and select a setting from F01 to F10 strobe time of 40 s to 40 ms The Light Units are turned ON for the period of time set on the setting switch after the exter...

Page 6: ...switch is at LOW if ether controls setting to ON setting Light unit will be turned ON 1 Send a data within 4 seconds from Header to Delimiter otherwise time out error occurs and command data will be r...

Page 7: ...The Control Units are identified with the ID switch settings Up to four Units can be connected to one signal line The EIA 485 communications circuit will be terminated inside the Control Unit if the...

Page 8: ...us Photocoupler OFF Photocoupler ON Light Unit status Trigger Logic Switch Set to LOW The Light Units turn ON when the photocoupler is ON and OFF when the photocoupler is OFF Trigger Logic Switch Set...

Page 9: ...output connector Is the AC cord inserted firmly into the AC inlet and a wall socket Does the digital window show an error Check the error display Is an appropriate Light Unit connected to the output...

Page 10: ...Y EXCLUDED EXCEPT AS EXPRESSLY SET FORTH HEREIN CCS MAKES NO WARRANTIES WITH RESPECT TO THE PRODUCTS WARRANTY PERIOD TWO YEARS STARTING FROM CCS Inc SHIPPING DATE CCS Inc WILL REPAIR OR REPLACE THE PR...

Reviews: