background image

22

2

Names and Functions of Parts

Channel Selection Switch

For external control with EIA-485 communications.

External Control Connector

External Trigger Input Connector

FG terminal

Output Connectors

(24V LIGHT) 

Fan Air Inlet

 (Left side)  

Fan Exhaust Outlet

 (Right side) 

Output Connectors 

(HLV LIGHT)

Setting Indicators

Channel Indicators

Press: Switches between the light intensity setting and lighting mode setting.

Press for at least 2 seconds: Locks the settings.

Rotate: Sets the light intensity or lighting mode.

Setting Switch

Displays the setting of the 

light intensity or the setting of 

the lighting mode.

Digital Window

Selects manual (MANU) or external (EXT) control mode.

Manual/External Mode Selector

Selects the logic of the trigger signal.

Trigger Logic Switch

Connects the power source to the Control Unit.

AC Inlet

BRT lit:    The light intensity can be set.

PLS lit:    The lighting mode can be set.

LOCK lit: The settings are locked.

Inputs the ON/OFF signal for ON/OFF Mode.

Inputs the trigger signal for Strobe Mode.

Sets the ID for recognition with EIA-485 communications.

ID Switch

Select the channel from L1 to L4. Only the channel 

on which Light Units are connected can be selected. 

The channels with same channel No. of 24V LIGHT 

and HLV LIGHT are operated simultaneously.

Ground the FG terminal.

Connect these connectors to the 24V DC Light Units.

(L1 to L4)

This is the air inlet for the cooling fan.

This is the air outlet for the cooling fan.

Connect these connectors to the Spotlights.

(L to L4)

The indicator for the selected channel will light.

When the L1 indicator is lit, the settings for the L1 Light 

Unit in the 24V Light Units (24V LIGHT) and the L1 Light 

Unit in the Spotlights (HLV LIGHT) can be changed.

Rear

DIN rail bracket x 1

Screws x 4

3

Installation

Do not place any objects within 20mm from the fan air inlets 
or fan exhaust outlets. Insufficient ventilation may cause 
heat to accumulate inside the product and result in a fire.

Mounting the Unit to DIN Rail

Mounting to DIN Rail

Hook the tab on the upper part of the Unit on the DIN rail and press the 

Unit in the direction indicated by arrow 2 while pressing it in the direction 

indicated by arrow 1.

Removing from DIN Rail

Press the Unit down in the direction indicated by arrow 3 and pull it out in 

the direction indicated by arrow 4.

DIN Rail

1

2

DIN Rail

3

4

WARNING

Mounting

Removing

1

Removing the Rubber Feet from the Bottom of the Unit

Remove the screws that hold the rubber feet in place using a Phillips 

screwdriver.

2

Securing the Brackets to the Base of the Unit

Secure the Brackets to the base of the Unit with the four screws that 

come with the Brackets.

3

Securing the Unit with Mounting Screws

Secure the Unit in place with mounting screws. The mounting screws must 

be provided by the user.

Securing the Unit with Base Brackets 

(Accessories)

* Attach the Bracket to the other side as well.

70

Two, 3.5 dia. 

holes

±0.2

±0.2

59.3

29

4-C2

40

Two, 4.5 dia. 

holes

19

5

 (1) 

5

10

Model: BK-PD3

Base Brackets

Rubber foot

Installation screw holes

(Insert the screws to a depth of no more than 5 mm 

 and use a tightening torque of 0.3 N·m max.)

M3 screws for the rubber feet

Screws for securing the Brackets to the mounting surface

(Prepare the mounting screws yourself according to the installation conditions.)

M3 screws for mounting the Brackets (M3, included with the Brackets)

Holes for the mounting screws (4.5 dia.)

Includes two Base Brackets and 

four mounting screws

 (+ one spare screw)

Do not remove the DIN rail bracket. If 
they must be removed and attached 
again, make sure that you use the original 
screws (or M3 × 4 mm screws). 
If other screws are used, they may 
short-circuit internal components and 
electric shock may occur.

Caution

Always use Base Brackets (model: BK-PD3) when securing the Unit at 

its base. If it is secured without the Brackets, the Unit may be damaged.

Caution

Summary of Contents for PD3-5024-4-SI

Page 1: ...esult in electric shock Make sure that the product is free of moisture or any liquid Doing so may result in fire or electric shock Before connecting or disconnecting cables make sure that the power so...

Page 2: ...lets or fan exhaust outlets Insufficient ventilation may cause heat to accumulate inside the product and result in a fire Mounting the Unit to DIN Rail Mounting to DIN Rail Hook the tab on the upper p...

Page 3: ...urned OFF with manual or external control To use ON OFF Mode or Strobe Mode connect the external trigger input cable to the external trigger input connector Insert the connector to the Light Unit all...

Page 4: ...nal control Variable current control Per connector 3 9 W max 700mA max Depends on the light intensity of the Light Unit Only connected Light Units can be selected Detected at any time 3 s 10 5 6 5 6 5...

Page 5: ...lash the strobe turn the setting switch and select a setting from F01 to F10 strobe time of 40 s to 40 ms The Light Units are turned ON for the period of time set on the setting switch after the exter...

Page 6: ...switch is at LOW if ether controls setting to ON setting Light unit will be turned ON 1 Send a data within 4 seconds from Header to Delimiter otherwise time out error occurs and command data will be r...

Page 7: ...The Control Units are identified with the ID switch settings Up to four Units can be connected to one signal line The EIA 485 communications circuit will be terminated inside the Control Unit if the...

Page 8: ...us Photocoupler OFF Photocoupler ON Light Unit status Trigger Logic Switch Set to LOW The Light Units turn ON when the photocoupler is ON and OFF when the photocoupler is OFF Trigger Logic Switch Set...

Page 9: ...output connector Is the AC cord inserted firmly into the AC inlet and a wall socket Does the digital window show an error Check the error display Is an appropriate Light Unit connected to the output...

Page 10: ...Y EXCLUDED EXCEPT AS EXPRESSLY SET FORTH HEREIN CCS MAKES NO WARRANTIES WITH RESPECT TO THE PRODUCTS WARRANTY PERIOD TWO YEARS STARTING FROM CCS Inc SHIPPING DATE CCS Inc WILL REPAIR OR REPLACE THE PR...

Reviews: