background image

55

4

Selecting the Lighting Mode

3

Setting the light Intensity

7

Manual Control

Make sure that the main power source is turned ON.
Set items       ,      , and       when using Continuous Mode or ON/OFF Mode.
Set items       ,      ,      , and       when using Strobe Mode.

1

3

4

2

1

3

2

Make sure that the LOCK setting indicator is 
not light and that the trigger logic switch is set 
to HIGH. Otherwise you may not be able to 
perform the rest of this procedure.

Set the Manual/External Mode Selector to MANU to 

set Manual Mode.

1

Setting the Manual/External Mode Selector to Manual

Check

Four channels from L1 to L4 are 
allocated to the 24V LIGHT and HLV 
LIGHT output connectors. When L1 is 
selected, settings for the L1 Light Unit 
for the 24V LIGHT connectors and the 
HLV LIGHT connectors can be 
changed. The 4 channels can be 
controlled separately.

2

Selecting the Channel

Press the channel selection switch to select the channel to set (L1 to L4). 
Only channels with Light Units connected to them can be selected.
(If a new Light Unit is connected, the lowest channel is automatically selected.)

Press.

Press the setting switch to light the PLS setting indicator.
Turn the setting switch to select the lighting mode from Continuous Mode, 
ON/OFF Mode, or Strobe Mode. (Default value:  

F00

  )

Press the setting switch to light the BRT setting indicator.
Turn the setting switch to set a value between 0 and 255.

(Default setting: 

255 

, Minimum: 

000 

, Maximum: 

255 

Press.

Press.

* The light intensities are theoretical values.

24V LIGHT

0.4

 (Dimly lit) 

0.8
1.2

99.6

100.0

Light intensity (%)

HLV LIGHT

0.0

 (Not lit) 

0.4
0.8

99.6

100.0

000

002

254
255

001

Digital Window

Locking Settings

When the setting switch is pressed for 2 
seconds or longer, the lighting mode and 
light intensity settings are locked, and the 
LOCK setting indicator lights. (The set values 
can be viewed.) Pressing the switch again for 
2 seconds or longer releases the lock.

4

Selecting the Lighting Mode (Continued)

Turn the setting switch and set   

F00

   to turn ON the Light Units continuously.

To flash the strobe, turn the setting switch and select a setting from   

F01

   to

  

F10

   (strobe time of 40 μs to 40 ms). The Light Units are turned ON for the 

period of time set on the setting switch after the external trigger signal is input.
The Strobe Mode can be set for 24V DC Light Units only.

Turn the setting switch and set   

F00

   to turn the Light Units ON and OFF.

The Light Units are turned ON or OFF according to the external trigger signal input.

40μs
80μs

120μs
200μs
600μs

Strobe Mode

 (The Strobe Mode can be set 

   for 24V DC Light Units only.) 

1ms
4ms

10ms
20ms
40ms

Continuous Mode / ON/OFF Mode

Status

Digital Window

F01
F02
F03
F04
F05
F06
F07
F08
F09
F10

F00

Press for 2 s.

Continuous Mode

ON/OFF Mode

(If the external trigger is not used, the Light Units are ON continuously.)

Strobe Mode

(If an external trigger is not used, the Light Units are OFF.)

For details on the external trigger input, refer to 9. Inputting the External Trigger.

Precautions for Channel Selection

Only channels with Light Units connected to them can be selected. If a Light Unit is removed 
without turning OFF the power supply, the channel for the Light Unit that is no longer connected 
may be selected. This does not indicate a malfunction. Check the following table for details.
There is risk of fire or electric shock. Make sure that the power supply is turned OFF when 
you connect Light Units or Spotlights.

The channel with the 

disconnected Light Unit 

can be selected.

The Light Unit was disconnected 

without turning OFF the power supply.

The channel with the 

disconnected Light Unit 

cannot be selected.

Operation

If there is an electrical connection, 

the Light Unit will light.

(The channel can be selected.)

The Light Unit does not turn 

ON or an HLV ID error occurs.

(The channel cannot be selected.)

A Light Unit that is not 

supported was connected.

Connector Connection Example

L2 and L4

Channels
can be selected for the 

and

:  L4

:  L 2

.

can be selected if the connections 

without turning OFF the power supply.

L1,  L2 and L3

Channels

and

:  L3

:  L 1

.

are changed to the following:

following connections:

Even if the Light Unit is disconnected, 

the channel can be selected until 

the power is turned OFF. 

(The settings are also retained.)

Summary of Contents for PD3-5024-4-SI

Page 1: ...esult in electric shock Make sure that the product is free of moisture or any liquid Doing so may result in fire or electric shock Before connecting or disconnecting cables make sure that the power so...

Page 2: ...lets or fan exhaust outlets Insufficient ventilation may cause heat to accumulate inside the product and result in a fire Mounting the Unit to DIN Rail Mounting to DIN Rail Hook the tab on the upper p...

Page 3: ...urned OFF with manual or external control To use ON OFF Mode or Strobe Mode connect the external trigger input cable to the external trigger input connector Insert the connector to the Light Unit all...

Page 4: ...nal control Variable current control Per connector 3 9 W max 700mA max Depends on the light intensity of the Light Unit Only connected Light Units can be selected Detected at any time 3 s 10 5 6 5 6 5...

Page 5: ...lash the strobe turn the setting switch and select a setting from F01 to F10 strobe time of 40 s to 40 ms The Light Units are turned ON for the period of time set on the setting switch after the exter...

Page 6: ...switch is at LOW if ether controls setting to ON setting Light unit will be turned ON 1 Send a data within 4 seconds from Header to Delimiter otherwise time out error occurs and command data will be r...

Page 7: ...The Control Units are identified with the ID switch settings Up to four Units can be connected to one signal line The EIA 485 communications circuit will be terminated inside the Control Unit if the...

Page 8: ...us Photocoupler OFF Photocoupler ON Light Unit status Trigger Logic Switch Set to LOW The Light Units turn ON when the photocoupler is ON and OFF when the photocoupler is OFF Trigger Logic Switch Set...

Page 9: ...output connector Is the AC cord inserted firmly into the AC inlet and a wall socket Does the digital window show an error Check the error display Is an appropriate Light Unit connected to the output...

Page 10: ...Y EXCLUDED EXCEPT AS EXPRESSLY SET FORTH HEREIN CCS MAKES NO WARRANTIES WITH RESPECT TO THE PRODUCTS WARRANTY PERIOD TWO YEARS STARTING FROM CCS Inc SHIPPING DATE CCS Inc WILL REPAIR OR REPLACE THE PR...

Reviews: