background image

33

External Control / External 

Trigger Input Cable 

(EXCB2-M10M20-3

)

External Control / External 

Trigger Input Cable 

(EXCB2-M10M20-3

)

External Trigger Input Cable

(EXCB2-M10-3)

External Trigger Input Cable

(EXCB2-M10-3)

External Control Cable

(EXCB2-M20-3

)

1

1

2

Press the connector in until it locks in place.

Release the lock and remove the connector.

4

Connections

1

Connect the LED Light

Connect the connecting cable to the LED Light Unit to the output connector on the Control Unit.

Insert the connector to the Light Unit all the way in.

Press the lock and pull out the connector.

SMP-03V-BC

SMP-03V-BC

ELR-02V

ELR-02V

3

Connect the External Control Cable

 (Optional item, sold separately)

4

Connect the External Trigger Input Cable

 (Optional item, sold separately)

To use ON/OFF Mode or Strobe Mode, connect the external trigger input 
cable to the external trigger input connector.

An optional External Trigger Input Cable  (EXCB2-M10-3) (sold separately) is available. 
In case using a self-made cable, cable length should be within 3 m at maximum.

Press the connector in until it locks in place.

Release the lock and remove the connector.

1

2

1

2

Before connecting the Control Unit, make sure that the main 
power source is turned OFF. Making connections with the 
power turned ON may result in a fire or electric shock.

WARNING

Connecting

Removing

Connecting

Removing

Connecting

Removing

To perform external control, connect the external control cable to the external control connector.

An Optional External Control Cable (EXCB2-M20-3) and an Optional External 

Control/External Trigger Input Cable (EXCB2-M10M20-3) is available. 

(The external control and external trigger input can be connected with one cable.)

In case using a self-made cable, cable length should be within 3 m at maximum.

1

2

1

5

What You Can Achieve with This Control Unit

Select the control mode and lighting mode from the following Application Guide and proceed to the indicated reference items.

The Light Units are always ON.

The Light Units are turned ON or 

OFF according to the external 

trigger signal input.

Power ON

Power OFF

Lit.

Not lit.

The Light Units are turned ON for 

a set time after the external trigger 

signal is input.

Control Mode

Lighting Mode

Front panel operation

External control using a PLC 

or image process device

Application Guide

9

Inputting the External Trigger

To use external control in Strobe Mode, 
refer to items       ,       ,       , and        under 

                                                               and 

                                                               .

1

3

4

2

8

Control with External Signals

To use external control in ON/OFF Mode, 
refer to items       ,       , and        under 

                                                               and 

                                                              .

1

3

2

9

Inputting the External Trigger

8

Control with External Signals

To use external control in Continuous Mode, 
refer to items       ,       , and        under 

                                                               .

1

3

2

8

Control with External Signals

9

Inputting the External Trigger

To use manual control in ON/OFF Mode, 
refer to items       ,       , and        under 

                                     and 

                                                           .

7

Manual Control

1

3

2

To use manual control in Continuous Mode, refer to 

items       ,       , and       under                                      .

7

Manual Control

1

3

2

9

Inputting the External Trigger

7

Manual Control

To use manual control in Strobe Mode, 
refer to items       ,       ,        and        under 

                                     and 

                                                           .

1

3

4

2

Photocoupler OFF

Photocoupler ON

Lit.

Not lit.

Not lit.

* When the Trigger Logic 

  Switch is set to HIGH

Photocoupler OFF

Photocoupler ON

Lit.

Not lit.

Not lit.

* When the Trigger Logic 

  Switch is set to HIGH

Continuous Mode

ON/OFF Mode

Strobe Mode

2

Connect the AC Cord

The AC cord that is included with the Unit is for 100 to 120V AC. We recommend using the 
following for 200 to 240V AC. Cable: GTCE-3 x 1.0 mm

2

 (manufactured by Kawasaki Electric 

Wire Company), Connector: KS-31AY (manufactured by Kawasaki Electric Wire Company)

Connect the power cord to the Control Unit and a wall socket. The Control Unit will turn ON when 

power is supplied from the main power source. When the Unit is ON, the digital window will light.

Digital Window

The light intensity of the 
lowest channel is displayed.

(Display when no Light 
 Unit is connected)

Connect the AC power cord to the AC inlet and a wall socket.

*Data that has been 

set is retained even 

after the power is 

turned OFF with 

manual or external 

control.

Connect 24V DC Light Units to the 24V LIGHT output connectors, and Spotlights to 
the HLV LIGHT output connectors. One of the 24V LIGHT output connectors is an 
ELR-02V connector for a High-output Light Unit.

Summary of Contents for PD3-10024-8-PI

Page 1: ...re or electric shock Do not use user made light cables Doing so may cause product failure Do not place the product in direct sunlight or in a high humidity environment Doing so may result in fire due...

Page 2: ...ndicated by arrow 2 while pressing it in the direction indicated by arrow 1 Removing from DIN Rail Press the Unit down in the direction indicated by arrow 3 and pull it out in the direction indicated...

Page 3: ...F according to the external trigger signal input Power ON Power OFF Lit Not lit The Light Units are turned ON for a set time after the external trigger signal is input Control Mode Lighting Mode Front...

Page 4: ...ight Units that are connected Check the following table before using the Light Units Continuous mode ON OFF mode Strobe mode Manual control External control SMP 03V BC ELR 02V SMP 03V BC ELR 02V Varia...

Page 5: ...t used the Light Units are OFF For details on the external trigger input refer to 9 Inputting the External Trigger Press Make sure that the main power source is turned ON Set items and when using Cont...

Page 6: ...trobe Mode 120 s Strobe Mode 200 s Strobe Mode 600 s Strobe Mode 1ms Strobe Mode 4ms Strobe Mode 10ms Strobe Mode 20ms Strobe Mode 40ms Make sure that the main power source is turned ON Set items and...

Page 7: ...ed 3 Black 3 Red 3 Black 3 Red 3 Black 3 Red 3 Light Intensity Input 8 bits Lighting Mode Value Input 4 bits Error Output Channel Selection 3 bits Light Intensity Write Lighting Mode Write EXCB2 M20 3...

Page 8: ...strobe light continues for the set time from that point ON OFF Mode Trigger Logic Switch Set to HIGH The Light Units turn ON when the photocoupler is OFF and OFF when the photocoupler is ON Strobe Mod...

Page 9: ...l Specifications PD3 Control Unit Photocoupler Error Output OC Error Output OE Error Output Load current If you have any problems during product usage please look up the cause in this chart If the sit...

Page 10: ...EXPRESSLY SET FORTH HEREIN CCS MAKES NO WARRANTIES WITH RESPECT TO THE PRODUCTS WARRANTY PERIOD TWO YEARS STARTING FROM CCS Inc SHIPPING DATE CCS Inc WILL REPAIR OR REPLACE THE PRODUCT FREE OF CHARGE...

Reviews: