background image

22

2

Names and Functions of Parts

For external control with parallel communications.

External Control Connector

External Trigger Input Connector

FG terminal

Output Connectors

(24V LIGHT) 

Fan Exhaust Outlet

 (Right side) 

Output Connectors 

(HLV LIGHT)

Setting Indicators

Press: Switches between the light intensity setting and lighting mode setting.

Press for at least 2 seconds: Locks the settings.

Rotate: Sets the light intensity or lighting mode.

Setting Switch

Displays the setting of the 

light intensity or the setting of 

the lighting mode.

Digital Window

Selects manual (MANU) or external (EXT) control mode.

Manual/External Mode Selector

Selects the logic of the trigger signal.

Trigger Logic Switch

Connects the power source to the Control Unit.

AC Inlet

BRT lit:    The light intensity can be set.

PLS lit:    The lighting mode can be set.

LOCK lit: The settings are locked.

Inputs the ON/OFF signal for ON/OFF Mode.

Inputs the trigger signal for Strobe Mode.

3

Installation

Do not place any objects within 20mm from the fan air inlets 
or fan exhaust outlets. Insufficient ventilation may cause 
heat to accumulate inside the product and result in a fire.

1

Removing the Rubber Feet from the Bottom of the Unit

Remove the screws that hold the rubber feet in place using a Phillips 

screwdriver.

2

Securing the Brackets to the Base of the Unit

Secure the Brackets to the base of the Unit with the four screws that 

come with the Brackets.

3

Securing the Unit with Mounting Screws

Secure the Unit in place with mounting screws. The mounting screws must 

be provided by the user.

Securing the Unit with Base Brackets 

(Accessories)

* Attach the Bracket to the other side as well.

Mounting the Unit to DIN Rail

Mounting to DIN Rail

Hook the tab on the upper part of the Unit on the DIN rail and press the 

Unit in the direction indicated by arrow 2 while pressing it in the direction 

indicated by arrow 1.

Removing from DIN Rail

Press the Unit down in the direction indicated by arrow 3 and pull it out in 

the direction indicated by arrow 4.

DIN Rail

1

2

Rear 

DIN Rail

3

4

70

Two, 3.5 dia. 

holes

±0.2

±0.2

59.3

29

4-C2

40

Two, 4.5 dia. 

holes

19

5

 (1) 

5

10

Model: BK-PD3

Base Brackets

DIN rail brackets x 2

Screws x 8

Always use Base Brackets (model: BK-PD3) when securing the Unit at 

its base. If it is secured without the Brackets, the Unit may be damaged.

Do not remove the DIN rail brackets. 
If they must be removed and attached 
again, make sure that you use the original 
screws (or M3 × 4 mm screws). 
If other screws are used, they may 
short-circuit internal components and 
electric shock may occur.

Caution

WARNING

Mounting

Removing

Rubber foot

Installation screw holes

(Insert the screws to a depth of no more than 5 mm 

 and use a tightening torque of 0.3 N·m max.)

M3 screws for the rubber feet

Screws for securing the Brackets to the mounting surface

(Prepare the mounting screws yourself according to the installation conditions.)

M3 screws for mounting the Brackets (M3, included with the Brackets)

Holes for the mounting screws (4.5 dia.)

Caution

Includes two Base Brackets and 

four mounting screws

 (+ one spare screw)

Channel Selection Switch

Select the channel from L1 to L8. Only the channel 

on which Light Units are connected can be selected. 

The channels with same channel No. of 24V LIGHT 

and HLV LIGHT are operated simultaneously.

Ground the FG terminal.

Connect these connectors to the 24V DC Light Units.

L1 to L8 (SMP-03V-BC), L1(ELR-02V)

Fan Air Inlet

 (Left side)  

This is the air inlet for the cooling fan.

This is the air outlet for the cooling fan.

Connect these connectors to the Spotlights.

L1 to L8 (SMP-03V-BC)

Channel Indicators

The indicator for the selected channel will light.

When the L1 indicator is lit, the settings for the L1 Light 

Unit in the 24V Light Units (24V LIGHT) and the L1 Light 

Unit in the Spotlights (HLV LIGHT) can be changed.

Summary of Contents for PD3-10024-8-PI

Page 1: ...re or electric shock Do not use user made light cables Doing so may cause product failure Do not place the product in direct sunlight or in a high humidity environment Doing so may result in fire due...

Page 2: ...ndicated by arrow 2 while pressing it in the direction indicated by arrow 1 Removing from DIN Rail Press the Unit down in the direction indicated by arrow 3 and pull it out in the direction indicated...

Page 3: ...F according to the external trigger signal input Power ON Power OFF Lit Not lit The Light Units are turned ON for a set time after the external trigger signal is input Control Mode Lighting Mode Front...

Page 4: ...ight Units that are connected Check the following table before using the Light Units Continuous mode ON OFF mode Strobe mode Manual control External control SMP 03V BC ELR 02V SMP 03V BC ELR 02V Varia...

Page 5: ...t used the Light Units are OFF For details on the external trigger input refer to 9 Inputting the External Trigger Press Make sure that the main power source is turned ON Set items and when using Cont...

Page 6: ...trobe Mode 120 s Strobe Mode 200 s Strobe Mode 600 s Strobe Mode 1ms Strobe Mode 4ms Strobe Mode 10ms Strobe Mode 20ms Strobe Mode 40ms Make sure that the main power source is turned ON Set items and...

Page 7: ...ed 3 Black 3 Red 3 Black 3 Red 3 Black 3 Red 3 Light Intensity Input 8 bits Lighting Mode Value Input 4 bits Error Output Channel Selection 3 bits Light Intensity Write Lighting Mode Write EXCB2 M20 3...

Page 8: ...strobe light continues for the set time from that point ON OFF Mode Trigger Logic Switch Set to HIGH The Light Units turn ON when the photocoupler is OFF and OFF when the photocoupler is ON Strobe Mod...

Page 9: ...l Specifications PD3 Control Unit Photocoupler Error Output OC Error Output OE Error Output Load current If you have any problems during product usage please look up the cause in this chart If the sit...

Page 10: ...EXPRESSLY SET FORTH HEREIN CCS MAKES NO WARRANTIES WITH RESPECT TO THE PRODUCTS WARRANTY PERIOD TWO YEARS STARTING FROM CCS Inc SHIPPING DATE CCS Inc WILL REPAIR OR REPLACE THE PRODUCT FREE OF CHARGE...