The electrolysis cell
As an essential component of your system, the cell is equipped with electrodes
consisting of titanium with ruthenium treated plates. It is specially designed to
guarantee a large lifespan and limit maintenance operations.
The cell integrates a flow switch which shuts down the electrolyser if there is an
absence of flow or during a backwash. It prevents any risk of an accumulation of
hydrogen or any excessive heat and therefore improves the security of the device.
It features LED lighting informing the user about physical parameters of water;
•
The
chlorine
production
is
off,
the
colour
depends
on
water
temperature;
•
The
chlorine
production
is
on,
the
colour
depends
on
water
salinity;
INSTALLATION
The
Limpido Z2
®
different elements to be placed on the pool pipework are the following:
-
PH probe must be located on the discharge after the filter.
-
Ph injector (PH- or PH+) is placed just before the outlet.
-
The cell is installed between pH probe and pH injector
-
If a heater is used, it has to be placed between cell and injector.
The cell can be installed on line or via by-pass. The by-pass installation means that a loss of pressure can be
prevented in the filtration circuit, the rate can be adjusted in the cell and the cell can be dismounted without
interrupting the filtration.
5°C
26°C
42°C
pH+
or pH-
30cm mini
IMPORTANT: the flow
switch must be installed
on the right direction
2g/l
3,5g/l
5g/l