4.2.2. Cover contact
For pools with an automatic cover, the quantity of chlorine produced must be lowered when the
pool is covered. Indeed, in this situation the water is sheltered from UVs and most pollutants, so
the amount of chlorine required is significantly less. Most covers are fitted with a travel switch to
which the Limpido XC2 can be connected to adjust its production.
This contact must be open when the cover is open, and closed when the cover is over the pool.
Use the cable passage at the back of the control box and connect the two contact wires directly to
the module (see photo below).
*The cover contact must imperatively be a dry contact with no electric poten-
tial. No other wires (coupling for other devices, etc.) must be connected at the
same location. A connection error can seriously damage the device and will void
the guarantee.
4.2.3. Cell connection
Connect the cell to the side connector and lock it in place using the metal staple supplied with the
accessories.