Technicalinst. guide
Limpido XC2
v4.0
This feature is used to reduce the risk of large amounts of chlorine accumulating.
6.6. Supervisor menu
6.6.1. Access to the Supervisor menu
Some of the functions on the device are reserved for use by installers or the persons in charge of
maintaining the device. To access the supervisor menus,
1.
Power off the electrolysis unit using the ON/OFF button on the control box,
2.
Wait for about 30 seconds,
3.
Press the key
and keep it pressed,
4.
Power the electrolysis unit back on using the ON/OFF button on the control box and release
the key,
5.
You will see
SUPERVISOR
displays, confirming supervisor mode.
6.6.2. System status (supervisor)
The following additional system status screens are available in supervisor mode;
Screen
Function
Salt level = 3.5g/
l
This screen provides a purely informational and experimental
indication of the salt level calculated using the water conductiv-
ity measurement. This calculation is made assuming a new cell
and the current it normally consumes without taking into con-
sideration its age. Whenever a salt level measurement is need-
ed, we recommend the use of an electronic salt tester (ref. T-
SEL, sold separately).
PROD 000h30
This screen gives an estimate of the number of operating hours
chlorine production.
6.6.3. GENERAL MENU (supervisor)
The following additional configuration screens are available in supervisor mode;
www.c-
cei.fr
21