Technicalinst. guide
Limpido XC2
v4.0
4.1.2. Water flow detector
The Limpido XC2 is shipped with a flow detector. The flow detector is built into the cell delivered
with the Limpido XC2.It prevents the electrolysis unit from running when there is no flow, or during
a backwash. It is used to prevent all risks of hydrogen accumulating or excess heating and thereby
makes the system safer.
1.
Install the fixing collar on the piping after having previously drilled it.
2.
Screw the male / male ¾" nipple into the fixing collar. (use Teflon tape to make sure it is
watertight)
3.
Screw on the flow detector (use Teflon tape to make sure it is watertight). Do not over-tighten
the detector.
Take special care over the water flow direction so that the device
correctly detects the flow. For the flow detector to be correctly
positioned, the arrow engraved on it must point in the direction
the water flows.
4.1.3. Earth electrode
The Pool-Terre device shipped with the Limpido XC2 is used to drain the water's electrostatic charge
to the earth. When this system is connected to a "proper earth" (the connection must be direct to a
local earth electrode), it eliminates leakage current and limits the reduction-oxidation phenomena
that cause corrosion.
1.
Install the fixing collar on the discharge piping after having drilled it, downstream from the
heating or electrolysis devices.
2.
Screw the electrode into the fixing collar. (use Teflon tape to make sure it is watertight)
3.
Connect the Pool-Terre directly to the earth electrode using a correctly sized green and yellow
wire. (minimum 4mm²)
www.c-
cei.fr
7