First reset the current settings to Factory Settings on the counter:
Scroll to 3-DSPLAY
Skip through the parameters until FACT SET is displayed. Change this to
YES by pressing RST
PRO NO should be displayed, Press SEL.
Continue to re-program the Counter by pressing and holding SEL to re-enter
programming mode. Pro-no will be displayed, press RST to move through the
relevant sections. The following parameters are required for the Tornado
counter:
Press RST Once:
Counter Parameters (1-INPUT)
INPA-B = Cnt ud
– if correct press SEL.
CNT A DP = 0 - if correct press SEL.
CNT A SCF = 0.0102 (Metric, m) or 0.0335 (Imperial, ft)
– once
correct press & Hold SEL.
CNT A RST = TO ZERO - if correct press SEL.
CNT A DIR = NOR - if correct press SEL.
CNT A LD = 0
– once correct press & Hold SEL.
CNT B BAT = NO - if correct press SEL.
RST P-UP = NO - if correct press SEL.
USER INP = NO - if correct press SEL.
Press RST Twice:
Rate Parameters (2-RATE)
RATE ENB = YES - if correct press SEL.
RATE DP = 0 - if correct press SEL.
RATE DSP = 60 - once correct press & Hold SEL.
RATE INP = 97.9 (Metric, m/min) or 29.8 (Imperial, ft/min)
–
once correct press & Hold SEL.
LO-UDT = 1.0 - if correct press SEL.
HI-UDT = 2.0 - if correct press SEL.
Press RST Three times:
DISPLAY (3-DSPLAY)
SEL ENB = YES - if correct press SEL.
RST ENB = YES - if correct press SEL.
D-SCROLL = NO - if correct press SEL.
D-COLOR = RED
– if correct press SEL.
D-LEVEL = 5 - if correct press SEL.
PRO CODE = 111
– CODE REQUIRED TO RE-PROGRAM -
once correct press & Hold SEL.
CODE VER = NO - if correct press SEL.
FACT SET = NO
– Press SEL Twice