Page 26 of 40
12.0 Procedure for changing the airbox infeed
guide
13.0 Procedure for changing the drive rollers
The machine is fitted with standard rollers, tests have shown that these rollers give a
good compromise of life and grip. There may be circumstances when a roller with
much higher grip will be needed. If, for instance it is necessary to install a cable, which
will sustain crushing damage when light compression forces are applied to it. It will be
necessary to use a roller with a surface coating with high friction characteristics. This
will allow the cable to be pushed with high torque whilst being compressed lightly. If
this type of roller is needed the CBS Products Ltd sales office will be able to advise on
part numbers etc. To fit this roller it will be necessary to remove the standard roller, the
procedure is as follows.
Remove the airbox infeed guide
Loosen and remove the (2) m3
fixing screws. (Do not mislay
these screws, they will be needed
to fix the new infeed guide.
Repeat the procedure for the
infeed guide insert in the other
hosing half
To fit the new guides, reverse
the disassembly procedure
Loosen and remove the
fixing screw and washer
Remove the roller
Repeat the procedure
for the other roller
To fit the new rollers,
reverse the assembly
procedure