The mains powered smoke alarm can be used together
with alarms in the
CAVIUS™
Wireless Family range:
Smoke, Heat, Flood, CO & mains power alarms. All
CAVIUS™ interconnected alarms within the Wireless
Family run on the same frequency and use the same
data protocol. This means that the wireless system can
consist of a combination of smoke, heat, flood etc.
Place all alarms into
‘Learn Mode’
and repeat
section 1.
Always test connection to all devices by repeating test
function section 6 after adding devices.
10.
ADD EXTRA DEVICE:
HEAT ALARM
SMART REMOTE
FLOOD ALARM
SMOKE ALARM
MAINS POWERE D
SMOKE ALARM
11.
LOW BATTERY SIGNAL:
Your product has a battery back-up with a 1 year life in
battery mode without mains power, and up to 10 years
normal life with mains. However, we recommend to
replace the battery every 5 years.
When the battery is starting its end of life, a short beep
will sound out every 48 seconds for 30 days.
Only the alarm with the low battery will sound, no
other connected alarms will sound. It is safe to change
batteries in the alarms without going through the learn
process again – they will not forget the codes during
the battery change process.
12.
BATTERY REPLACEMENT:
To replace the battery, detach the smoke alarm from the
power supply unit by twisting counterclockwise.
Remove the plastic cover to access the battery.
Replace the battery respecting the polarities. Attach the
alarm on power supply unit by twisting clockwise until it
clicks, and test the alarm.
13.
MAINTENANCE & TROUBLE SHOOTING:
The smoke alarm should be vacuum cleaned once per
quarter, to remove dust particles, and it can be wiped
with a damp cloth. (Do not open the alarm).
NOTE:
You can easily vacuum clean the smoke chamber
through the dedicated slot in the top cover, and it’s
possible to test the alarms by pressing the cover at the
same time.
High humidity condensing which can be resolved by
drying the smoke alarm.
If the smoke alarm does not work when the test button
is pushed, the probable cause is a power failure. Always
test the alarm after replacement of battery.
If the problem continues, please visit
www.cavius.co.nz
or
www.cavius.com.au
for any trouble shooting.
14.
OTHER INFORMATION:
Do not paint the alarm.
Disposal: F
or battery and product, please dispose
properly at the end of life. This is electronic waste which
should be recycled at an authorised e-waste facility
.
WARNING:
Please remove dust cover after installation.
Smoke will not be able to reach the chamber while the
dust cover is in place.
All Rights reserved: CAVIUS™ Aps assumes no
responsibility for any errors, which may appear in this
manual. Furthermore, CAVIUS™ Aps reserves the right
to alter the hardware, software, and/or specifications
detailed herein at any time without notice, and
CAVIUS™ Aps does not make any commitment to
update the information contained herein. All the
trademarks listed herein are owned by their respective
owners. Copyright © CAVIUS™ Aps.
127126 rev 1
MANUFACTURED BY:
Aps
Julsøvej 16 - DK8600 Silkeborg
www.cavius.com - [email protected]
Manufactured in P.R.C.
DISTRIBUTOR INFORMATION:
New Zealand:
CAVIUS NANO LTD.
8 King Street, Te Puke. 3119,
Bay Of Plenty 3118. P.O Box 11241, Palm Beach Plaza,
Papamoa, Bay Of Plenty 3151, New Zealand.
www.cavius.co.nz
PH:
0800 766533
or
07 542 219
Australia:
REPELEC (AUST)
Locked Bag 45, Plumpton, NSW 2761, Australia.
www.cavius.com.au
PH:
1300 555 586
WARRANTY:
Your CAVIUS™ smoke alarm has a 5 year warranty
from the date of purchase against defect in material
and workmanship (excludes the battery). Faulty units
during this period can be returned to the place of
purchase. You must provide the proof of purchase date
and such defects will be repaired, or replaced at the
distributors option, without charge. This Warranty only
covers defects in materials or workmanship in normal
residential use and does not cover damage resulting
from negligent handling, misuse or lack of reasonable
care. This warranty is in lieu of any other warranty
either expressed or implied.
Alarm condition aural signal pattern according to
ISO 8201.
4