All alarms to be connected in the house should be put 
into 

‘Learn Mode’

 by sliding the switch on the back of 

the alarm to the 

‘Learn Mode’

 position.

As the other alarms receive the specific house code, 
they will also flash the 

LED

 light.

When all alarms flash the red 

LED

, they are connected 

and can be switched out of ‘Learn Mode’ and installed.

The distance between interlinked alarms depends on 
the house layout and they should always be tested after 
installation. It is not advised to install alarms with a 
separation of more than 10m.

Diameter:

 97mm. Height: 41mm (without mounting 

base) 52mm (with mounting base).

Interlinked by RF:

 926.365 MHz

Complies to standards:

 AS3786:2014

Mains powered smoke alarm device
Model number: 2203-002
Developed by 

CAVIUS™

This smoke alarm is designed for private homes.

TECHNICAL INFORMATION

The smoke alarm is powered by mains power (110-
230V AC), with a lithium CR2 back-up battery. 
It can be Radio Frequency (RF) interlinked with other 
2203 alarms and with other CAVIUS™ Wireless Family 
alarms. The maximum number of alarms that can be 
interlinked within a house group are 32.

Please note:

 These must be alarms from the CAVIUS™ 

Wireless Family range.

CHAMBER

FILTER

OPTIONAL HOLE 

FOR LAMP WIRE 

TEST BUTTON

SIREN

RED & GREEN LED

1.

 HOW TO SET UP AND CONNECT ALARMS:

Start by pulling out the battery isolation strip in the 
battery compartment as shown.

Please note:

 RF connection is done with the device 

powered with battery only. You do not have to connect 
the power supply unit. The product label must not be 
removed as it contains important information regarding 
the product.

MAINS

POWERED

SMOKE ALARM

 

ISOLATION 

STRIP

 

 

1

NORMAL MODE

2

LEARN MODE

1

2

PLEASE READ THE USER GUIDE 

CAREFULLY BEFORE INSTALLATION AND 

RETAIN FOR FUTURE USE.

Please note:

 The learn switch placed on the back of 

the alarm can only be in learn position when the alarm 
is disassembled from the power supply unit. The learn 
switch will automatically switch to normal position 
when the alarm head is fitted to the power supply unit.
The red 

LED

 will light up to indicate that 

‘Learn Mode’

 

has been selected.

Do not remove the battery during ‘Learn Mode’ as  
this will interrupt the learn process. Press and hold the 
test button on one alarm only, until it beeps and the 
LED flashes. This alarm will become the master and will 
start sending out a specific house code to the  
other alarms.

2.

 THE BEST AREAS TO INSTALL THE SMOKE ALARM:

• Note the local country regulations regarding installation  
  and compliance.
• Note the local regulations and information for insurance  
  company policy regarding installed smoke alarms.
• Install an alarm between possible fire sources and  
  bedrooms as a minimum.
• Install alarms on each floor of the house, in hallways and  
 stairways.
• Alarms in each room such as bedrooms and living rooms.
Additional alarms increase the security.

3.

 AREAS WHERE NOT TO INSTALL SMOKE ALARMS:

• In dusty rooms
• At the top of a high pointed ceiling, in ceiling corners,  
  and within 50cm of a wall.
• In rooms where temperature goes outside the range  
  +4° to 38°C or above 90% relative humidity not  
 condensing.
• In kitchens, garages, laundries, or too close to  
  fireplaces; areas where either dampness, gases or  
  smoke could occur.
Place the alarm where it is reachable in order to test the 
alarm and for maintenance.

Smoke

Heat

Minimum 50cm from wall

Wall

Ceiling

Minimum 50cm

from peak.

Ceiling

1

Summary of Contents for 2203-002

Page 1: ...e product MAINS POWERED SMOKE ALARM ISOLATION STRIP 1 NORMAL MODE 2 LEARN MODE 1 2 PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE Please note The learn switch placed on the back of the alarm can only be in learn position when the alarm is disassembled from the power supply unit The learn switch will automatically switch to normal position when the alarm head is ...

Page 2: ...n of the alarm while the building is under construction The dust cover must be removed after the building is fully cleaned OPTION 1 ALARM MOUNTED ON MOUNTING BASE ON THE CEILING Use the mounting base ring to mark the screw holes on the ceiling For surface wiring pass the feed wire through the mounting base cable holder and screw after termination Connect the 3 wires to the power supply unit Live f...

Page 3: ...rter test all of your alarms to ensure they are operating correctly and are within range of each other It is recommended to check visually every week if the LED flashes correctly every 48sec Press the test button on any alarm for at least 10 seconds This will send out a test signal from the alarm all other connected alarms should receive the signal within a short time The alarms will emit a short ...

Page 4: ...alarm does not work when the test button is pushed the probable cause is a power failure Always test the alarm after replacement of battery If the problem continues please visit www cavius co nz or www cavius com au for any trouble shooting 14 OTHER INFORMATION Do not paint the alarm Disposal For battery and product please dispose properly at the end of life This is electronic waste which should b...

Reviews: