background image

Please read this Manual carefully before attempting to install this system.

BEFORE INSTALLING THE BW-1500 CHALLENGER PLUS

• DO read through this installation manual.
• DO NOT install the alarm brain in an engine compartment.
• The alarm may arm itself when power is first connected.This is a normal condition.

ITEMS SUPPLIED WITH THE BW-1500

BWS-1501 Receiver and Control Module

BWS-180 LED Status Indicator

BWS-385 2-Button, 2-channel, Code

BWS-12015 Wiring Harness, Fuseholder,

Learning Transmitters  (2)

and  Fuse

BWS-220 20 W, 120 dB Siren

SPDT Relay                       

BWS-295 Electronic Shock Sensor

BRS-003 Relay Socket

BWS-260 Valet Switch               

OPTIONAL ACCESSORIES

Backup Battery ....................................................BWS-500

Radar Field Sensor...........................................MAS-2

Remote Starting ....................................................RAS-101

Window Rollup..............................................WRM-2

Leather Transmitter  Case.................................BWS-390

Power Door Lock..........................................PDL-50

Trunk Release ...........................................................TR-100

SPECIFICATIONS

Operating voltage ...............+12 VDC Neg. Ground
Code Learning ......................................3 Codes Max.
Current consumption .........5 mA (max) disarmed.
Siren output drive ......................................3 Amperes
Automatic reset........................................60 seconds.
Door Lock/Unlock Output ...................(-) 500 mA.
Channel 2 Output Drive ........................(-) 500 mA.

Remote control transmit freq.............................310 mHz.
Passive arming delay ............................30 Seconds approx.
Auxiliary output drive..........................250 mA maximum.
Flashing output drive ............................10 Amp maximum.
Trigger inputs..............................................1) Neg. pnswtch.
1) Pos. pnswtch. 1) Neg. sensor or aux. pnswtch.

BW-1500

CHALLENGER

PLUS

I N S T A L L A T I O N   M A N U A L

Summary of Contents for BW-1500 CHALLENGER PLUS

Page 1: ...Shock Sensor BRS 003 Relay Socket BWS 260 Valet Switch OPTIONAL ACCESSORIES Backup Battery BWS 500 Radar Field Sensor MAS 2 Remote Starting RAS 101 Window Rollup WRM 2 Leather Transmitter Case BWS 390 Power Door Lock PDL 50 Trunk Release TR 100 SPECIFICATIONS Operating voltage 12VDC Neg Ground Code Learning 3 Codes Max Current consumption 5 mA max disarmed Siren output drive 3 Amperes Automatic re...

Page 2: ...220 Siren under the vehicle s hood Mount it away from heat sources such as radiators exhaust manifolds and turbochargers Mount it in an area where it will not be in the way for mechanics and so that it cannot be easily reached from below the vehicle Mount it so that its opening points down to prevent it from collecting water snow or ice Connect its BLACK wire to a good clean GROUND point and its R...

Page 3: ...re continuing with the alarm checkout A Turn the adjustment screw until the unit s LED reacts to your slapping various parts of the vehicle s body B Turn CLOCKWISE for more sensitivity COUNTER CLOCKWISE for less C DO NOT overadjust the sensor or false alarms may result 13 Connect the Main 14 Pin Wiring Harness to the BW 1501 Receiver and Control Module 14 To Power up and enter Transmitter Code Lea...

Page 4: ...Interrupt See Wiring diagram for connections 7 Red Blk LED Connect to the BLACK wire of the BWS 180 LED 8 Wht Yel Channel 2 Negative output when 2nd button is pressed The output will continue for as long as the button is held down See the diagram on Page 5 9 Blue Trip Negative trip input for connection to an external shock or motion sensor 10 Violet Valet Connect to theVALET switch This switch is ...

Page 5: ...ON SWITCH SIREN STARTER INTERRUPT RELAY 12VDC Ignition 12V MUST NOT DROP OUT during starting of vehicle DIP SWITCH SEE BOXED INFORMATION BLACK ANTENNA BLACK GREEN VIOLET WHITE YELLOW RED BLACK GRAY YELLOW GREEN BLACK ORANGE WHITE ORANGE DIP SWITCH PROGRAMS 1 Selects 75 or 3 seconds for door lock unlock pulse 2 Selects ignition lock unlock feature 3 Selects passive active lock 4 Selects passive act...

Page 6: ...87a 85 30 86 87a 12V FUSED CONSTANT LOCK YELLOW WIRE FROM ALARM GREEN WIRE FROM ALARM If the power trunk re lease requires a posi tive pulse to operate use this circuit 87 85 30 86 87a 2nd CHANNEL AUXILIARY BROWN WIRE 12V POSITIVE OUT TO TRUNK 12V 87 85 30 86 87a 85 30 86 87a YELLOW WIRE FROM ALARM GRN BK WIRE FROM ALARM 87 85 30 86 87a 85 30 86 87a REVERSE POLARITY DIRECTLY TO AD ON ACTUATORS GRO...

Page 7: ...r but will wire is shorted to ground VIOLET wire for shorts not passively arm Remote Control does Defective Remote Control Bad Replace Remote Control or its not arm or disarm battery Antenna wire is battery Un ground antenna alarm grounded Valet does not work Wire from Valet switch to ground Test for switched ground at alarm is not connected to a good ground unit Repair or replace as needed or wir...

Page 8: ...purchase ship defective unit prepaid to Black Widow Division DLC Inc along with 20 00 U S 30 00 Canadian cashier s check or money order to cover cost of handling Proof of purchase by the original owner must accompany warranty request before service is rendered This warranty covers normal use It does not cover damage from alteration misuse abuse accident improper installation or maintenance Warrant...

Reviews: