background image

Funk-Rauchwarnmelder
Smoke Alarm Device with Radio Link

Betriebsanleitung
Operating Manual

XSD200

Summary of Contents for XSD200

Page 1: ...Funk Rauchwarnmelder Smoke Alarm Device with Radio Link Betriebsanleitung Operating Manual XSD200 ...

Page 2: ... EU Nr 305 2011 gemäß EN 14604 2005 AC 2008 1772 CPR 140141 15 Variante V3 Content Content 1 Notes on the operating manual 43 2 Safety instructions 46 3 Overview 50 4 Location selection 53 5 Installation 59 6 Initial activation and setting up 63 7 Expanding a radio group and learning mode 66 8 Setting up a shared radio group 67 9 Connection test 68 10 Restoring default settings 69 11 Alarm forward...

Page 3: ...ufer dieses Gerätes das bei einem autorisierten Fachhändler erworben wurde für die Dauer von 10 Jahren ab dem Kaufdatum unter be stimmungsgemäßen Einsatz und Wartungsbedingungen ein mängelfreies Gerät Von der Garantie ausgeschlos sen sind äußere Umgebungseinflüsse wie z B Insekten oder Staubbefall Die Garantie erlischt zu dem auf dem Label aufgedruckten Austauschdatum des Rauchwarnmelders Weiterfü...

Page 4: ...reinstellungen an den Hersteller wenden 2 3 Nichtbestimmungsgemäße Verwendung Das Gerät dürfen Sie nicht für folgende Zwecke verwenden Wärmemelder im Sinne der EN 54 5 drahtloser Rauchmelder Brand melder im Sinne der EN 54 25 jede Verwendung die nicht in dieser Betriebsanleitung ausdrücklich als zulässig beschrieben ist 2 4 Maximale Nutzungsdauer Nutzungsdauer von 10 Jahren sowie eine La gerung vo...

Page 5: ...hmen Empfindliche Komponenten Empfindliche Komponenten Das Gerät besteht aus empfindlichen Komponenten z B Sensoren f Werfen Sie das Gerät nicht f Lassen Sie das Gerät nicht fallen f Üben Sie keinen Druck auf das Gerät aus f Tauchen Sie das Gerät nicht ins Wasser Gerät öffnen Das Gerät ist ein geschlossenes Sys tem Jeder Eingriff in das Gerät hat neben dem Verlust der beschränkten Garantie und der...

Page 6: ...rf an bestimmten komplexen und ggf kaskadierenden Verbindungsfunktionen bei der Alarmweiterleitung haben wenden Sie sich an den Hersteller siehe Kapitel 15 Zubehör Ersatzteile und Service auf Seite 38 3 2 Bedienelemente 1 2 4 3 5 7 6 Abb 1 Bedienelemente 1 Splint Aktivierungssicherung 2 Aktivierungstaste 3 Magnetträger 4 Signal LED 5 Funk Taste 3 Übersicht Abb 1 Bedienelemente 1 Splint Aktivierung...

Page 7: ...ortauswahl 4 Standortauswahl Mindestausstattung optimale Ausstattung in Berlin und Brandenburg Pflicht unter Vorbehalt wegen Wasserdampf nicht montieren Fluchtweg Dachboden Gästezimmer Büro Schlafzimmer Kinderzimmer Wohnzimmer Küche Heizung Werkraum Schlafzimmer Bad Küche Flur Wohnzimmer Kinderzimmer Kinderzimmer DG OG EG KG Abb 2 Standortauswahl Splint Aktivierungssicherung Der Splint Aktivierungs...

Page 8: ...er folgenden Punkte zutrifft Überwachungsfläche größer 60 m2 Raumhöhe größer 6 m hohe Teilwände raumtrennende Möbelstücke Deckenfelder Höhe größer 20 cm bei Unterzügen Fläche Deckenfelder größer 36 m2 Podest Galerie Fläche größer 16 m2 mindestens 2 m lang und breit Bei Räumen mit Unterzügen z B Holzbalken ist die Anzahl und Anordnung der Geräte abhängig von der Höhe der Unterzüge und von der Fläch...

Page 9: ...ei Deckenabsätzen den höchst gelege nen Montagepunkt auswählen f Geräte waagerecht zum Montageunter grund montieren Schmale Räume oder Flure Schmale Räume oder Flure zwischen 1 und 3 m breit zwischen 1 und 3 m breit Beachten Sie zusätzlich Folgendes bei der Fluren die zwischen 1 und 3 m breit sind f weniger als 7 5 m Abstand zwischen Stirnfläche Ende des Flures und dem ersten Gerät einhalten f wen...

Page 10: ...ndfläche 6 m Grundfläche 6 m Eine Ausnahme bilden schmale Räume und Flure die eine Grundfläche von weniger als 6 m2 haben Bei dieser Montagesituation können Sie die Geräte auch an der Wand montieren f Gerät mittig an der längeren Wand positionieren f Gerät 0 5 m unterhalb der Raumdecke erlaubt nicht erlaubt Beachten Sie Folgendes wenn die gera de Montagefläche mindestens 1 m lang und 1 m breit ist...

Page 11: ...gehal ten Der Magnetträger kann durch Kleben oder Bohren montiert wer den Um Verletzungen durch unsachge mäße Montage vorzubeugen sind die Hinweise in dieser Anleitung zwingend anzuwenden sowie die allgemeinen Sicherheitsvorschriften zu beachten VORSICHT Mögliche Sachschäden Durch dasVerwenden eines anderen Befestigungsmittels nicht mitgeliefert oder durch falscheVoraussetzungen am Montageort kann...

Page 12: ...ragfähig fest trocken frei von Fett Staub und losen Anstrichen etc ist stark magnetisch anziehend wirkt 5 1 Klebemontage Den Magnetträger können Sie wie folgt mittels Klebemontage montieren wartungsfreundlich und abnehmbar nach EN 14604 2005 AC 2008 oder wartungsunfreundlich aber diebstahlsicher nach EN 14604 2005 AC 2008 und vfdb 14 01 Q Klebemontage nach EN Klebemontage nach EN 14604 2005 AC 200...

Page 13: ...Anwendungen kann es sinn voll sein eine Gemeinschafts Funk Grup pe einzurichten z B im Flur eines Mehr familienhauses Eine zentrale Funk Grup pe Flur die mit einer oder mehreren anderen Funk Gruppen Wohnungen verbunden wird übernimmt dabei die Funktion der Gemeinschafts Funk Grup pe Die übrigen Funk Gruppen bilden die Neben Funk Gruppen Alarmsignale werden von einer alarmierten Neben Funk Gruppe n...

Page 14: ...ät kurz dru cken Signal LED aus 5 Funk Gruppe ist in Betrieb S i g n a l L E D s a l l e r Funk Gruppen Teilnehmer erlischen ebenfalls f Zur Überprüfung Verbindungstest durchführen siehe Kapitel 9 1 Ver bindungstest der Funk Gruppe auf Seite 29 Um ein weiteres Gerät hinzuzufügen gehen Sie wie folgt vor 5 Splint seitlich von der Aktivierungs taste herunter schieben 6 Aktivierungstaste bündig ein dr...

Page 15: ...führen siehe Kapitel 9 2 Verbindungstest zur Gemein schafts Funk Gruppe auf Seite 30 9 Verbindungstest 9 1 Verbindungstest der Funk Gruppe Die korrekte Verbindung einer Grup pe Funk Gruppe oder Gemein schafts Funk Gruppe können Sie wie folgt testen 1 Prüf Stopp Taste eines beliebigen Gerätes der Gruppe für ca 12 Sekunden gedrückt halten Nach ca 1 Sekunde ertönt der Prüfton 2 Nach dem zweiten Prüft...

Page 16: ...unk Gruppe aufheben DieZuordnungeinesGeräteszueinerFunk Gruppe müssen Sie in den folgenden Fällen aufheben Gerät aus einer bestehenden Funk Gruppe entnehmen und in einer anderen Gruppe neu anlernen defektes Gerät aus der Funk Gruppe entfernen In der Funk Gruppe aus der das Gerät entnommen wurde müssen Sie alle Ge räte in den Auslieferungszustand zurück setzen und neu anlernen f Kapitel 6 1 Funk Gr...

Page 17: ...iterleitung noch nicht stattgefunden hat Wenn die Alarmweiterleitung noch nicht stattgefunden hat können Sie den Alarm direkt am Alarm auslösenden Gerät stoppen f Prüf Stopp Taste am Alarm auslö senden Gerät drücken 5 Alarm ist gestoppt und wird nicht weitergeleitet Alarm Stopp wenn Alarmweiterleitung bereits stattgefunden hat Wenn die Alarmweiterleitung in einer Funk Gruppe bereits stattgefunden ...

Page 18: ... tönt alle 90 Sekunden ein zweifacher Ton siehe Kapitel 17 Alarm und Hinweistöne auf Seite 83 Gehen Sie wie folgt vor 1 Prüf Stopp Taste drücken um die Kontaminationsmeldung für 24 12 1 Störmeldungen Als Störmeldungen gelten die folgenden Meldungen Batteriestörungsmeldung Kontaminationsmeldung Alarm ohne Brandursache fehlerhafter Verbindungs test Funk Gruppe GEFAHR Gefahr durch Funktionsstörung Be...

Page 19: ... erweitern und Lernmodus auf Seite 28 4 Ggf Gerät in den Auslieferungs zustand bringen siehe Kapitel 10 Auslieferungszustand wiederher stellen auf Seite 31 5 Funk Gruppe erweitern siehe Ka pitel 7 Funk Gruppe erweitern und Lernmodus auf Seite 28 Funk Gruppe nicht oder nicht mehr im Lernmodus Wenn ein Gerät nicht mit einer Funk Grup pe verbunden werden kann und die Si gnal LEDs der Geräte der Funk ...

Page 20: ...egelmäßig mindestens einmal im Jahr einen Prüfton aus f Prüf Stopp Taste für ca 2 bis 3 Sekunden drücken kurzer Prüfton Einzelgerät Wenn Sie den Probealarm inner halb von weniger als 10 Minuten wiederholen ertönt bei bestimm ten Gerätevarianten ein zweifa cher kurzer Prüfton Prüfton Funk Gruppe Lösen Sie regelmäßig mindestens einmal im Jahr einen Prüfton aus f Kapitel 9 1 Verbindungstest der Funk ...

Page 21: ...tivierungstaste heraus 1 Abb 9 Aktivierungstaste herauszie hen 1 Aktivierungstaste 14 2 Endgültige Außerbetriebnahme Der Rauchwarnmelder hat nach spätes tens 12 Jahren seine bestimmungsgemä ße und zugleich maximale Nutzungsdau er erreicht f Tauschen Sie das Gerät mit Ablauf dieser Nutzungsdauer aus 14 3 Entsorgung Dieses Produkt darf gemäß ElektroG nicht in den Hausmüll gelangen f Senden Sie das z...

Page 22: ...ine 14 01 Q 2014 53 EU RED Regulation EU No 305 2011 according to EN 14604 2005 AC 2008 For more information about the Q label and the vfdb guideline please visit our website at pyrexx com 1772 CPR 210050 21 Variante V3 Q We are glad that you have chosen our product and we would like to thank you for your trust This operating manual contains informa tion and instructions for safe assembly activati...

Page 23: ...and must always be kept at hand near the installation location 1 5 Symbols used Various markings and symbols are used in the text in the operating manual These are explained below Warning symbol in warning labels Additional information and guidelines 1 Numbered action steps f Symbol for an instruction or a required action 5 Result of an action Symbol for a list 1 6 Copyright All rights are reserve...

Page 24: ...e fol lowing purposes Heat detection in terms of EN 54 5 Wireless smoke detection fire detection in terms of EN 54 25 Any use that is not expressly described as permitted in this operating manual 2 4 Maximum useful life The smoke alarm device will reach the end of its useful life at the lat est after 12 years of usage accord ing to the intended purpose The 12 years mentioned here are divid ed into...

Page 25: ...lfunc tion and damage to the device and the battery Opening the device Opening the device The device is a closed system Any tam pering with the device in addition to the loss of the limited warranty and statutory warranties also means that the device must not be used as intended f Öffnen Sie das Gerät nicht Als Ausnahme dürfen Sie die Prüf Stopp Taste Abdeckung des Rauchwarnmelders zum Identifizie...

Page 26: ... to shared radio group Repeater function If you need specific complex and possibly cascading connection functions for the alarm forwarding please contact the manufacturer see chapter 15 Accessories spare parts and product support on page 79 3 2 Components 3 2 Controls 1 2 4 3 5 7 6 Fig 1 Controls 1 Splint pin activation backup 2 Activation button 3 Magnetic carrier 4 Signal LED 5 Radio button 3 1 ...

Page 27: ...rrow It is used to set up the radio connection between devices Smoke intake lamellas Smoke from the fire reaches the inside of the device through the smoke intake lamellas and can then be detected by sensors Testing stop button smoke alarm device cover The testing stop button smoke alarm device cover is used for a self test for correct wireless connection between multiple devices or between device...

Page 28: ...sed by steam can be excluded 16 m2 at least 2 m long and wide In rooms with beams e g wooden beams the number and arrangement of the devices depends on the height of the joists and the surface formed by the beams 4 2 Requirements for the monitoring area When selecting the appropriate monitor ing area observe the following f Position the device centrally on the ceiling f Position the master or shar...

Page 29: ...ice with Radio Link In this installation scenario you can mount the devices on the wall f Position the device centrally on the longer wall f Mount the device 0 5 m below the ceiling Rooms with slanted ceilings Rooms with slanted ceilings slope angle 20 slope angle 20 In rooms with ceiling slope angles of more than 20 to the horizontal position heat pads can form in the ceiling peak that impede the...

Page 30: ...mounting surface less than 1 m long and 1 m wide Allowed Not allowed Note the following for straight mounting sur face less than 1 m long and 1 m wide f Observe chapter Rooms with slanted ceilings slope angle 20 on page 54 4 4 Rooms with a platform or gallery 0 5 1 2 0 5 0 5 16 m 2 m 1 2 Fig 7 Rooms with a platform or gallery Allowed Not allowed Note the following for rooms with platforms or galle...

Page 31: ...on and setting up on page 63 5 Position the device on the magnet carrier 5 The device is mounted on the magnet carrier The ultimate strength of the adhe sive bond is achieved after about 72 hours Adhesive mounting according to EN 14604 2005 AC 2008 and vfdb 14 01 Q To establish a permanent connection between the device and magnet carrier e g as theft protection you can addi tionally mount the devi...

Page 32: ... können Sie wie folgt mittels Klebemontage montieren wartungsfreundlich und abnehmbar nach EN 14604 2005 AC 2008 oder wartungsunfreundlich aber diebstahlsicher nach EN 14604 2005 AC 2008 und vfdb 14 01 Q Klebemontage nach EN Klebemontage nach EN 14604 2005 AC 2008 14604 2005 AC 2008 Gehen Sie bei dieser Montageart wie folgt vor 1 Magnetträger vom Gerät entfernen f dazu Magnetträger ankippen 2 Dril...

Page 33: ... LED lights up radio group from an alarming subgroup and trigger it Alarm forwarding from the shared radio group to the subgroup does not occur f Set up all the individual groups one after another before connecting the individual radio groups Fig 8 Flat 1 Flat 2 Corridor Flat 3 Flat 4 Alarm direction Example of shared radio group Flat subgroup Corridor shared radio group Alarm direction towards th...

Page 34: ...n as soon as the LED goes out 5 The radio group is in learning mode for a maximum of 10 minutes 3 To add further devices see steps 5 and 6 in chapter 6 1 Setting up the radio group on page 64 8 Setting up a shared radio group 8 1 Connecting radio groups To connect radio groups with another proceed as follows 1 Put the shared radio group into learning mode f See steps 1 and 2 in chapter 7 Expanding...

Page 35: ... the test stop key after the third test tone approx 24 seconds All devices of the community radio group and the device of the main group that is con nected to the community radio group emit a short test tone 3 Repeat for further secondary radio groups if necessary 5 5 Successful connection test of the community radio group 10 Restoring default settings In the following situations you must re store...

Page 36: ...he alarm 5 Alarm is stopped and will not be forwarded Alarm stop if the alarm forwarding Alarm stop if the alarm forwarding has already occurred has already occurred If the alarm forwarding has already tak en place in a radio group and you can identify the alarm triggering device pro ceed as follows f Press the testing stop button on the device triggering the alarm 12 Fault and error messages The ...

Page 37: ...ets clothing blankets and pillows Pollen construction sanding or fine dust Insects or micro organisms that have overcome the insect barriers of the device Strong cooking water and or frying fumes and room fragrance and insect repellent sprays Extreme temperature fluctuations or very strong electromagnetic radiation in close proximity influence the device Cigarette smoke only trig gers an alarm whe...

Page 38: ...the distance between the devices if necessary reduce the distance 2 Reactivate the devices and radio group f Reset all devices to the factory settings see chapter 10 Restoring default settings on page 69 f Reactivate the devices and radio group see chapter 6 Initial activa tion and setting up on page 63 Defective connection test Defective connection test of a radio group of a radio group A defecti...

Page 39: ... f Observe chapter 9 1 Radio group connection test on page 68 f Observe chapter Defective connection test of a radio group on page 74 Test tone to the shared radio group Test tone to the shared radio group Regularly trigger a test tone at least once a year f Observe chapter 9 2 Connection test to the shared radio group on page 68 13 2 Cleaning Perform the cleaning at least once a year Observe the ...

Page 40: ...nd a direc tory of the return facilities online at ear system de ear verzeichnis sammel und ruecknahmestellen jsf f Please note that the environment can be damaged by improper disposal 15 Accessories spare parts and product support 15 1 XSD200 accessories PX iP gateway for XSD200 radio networks Pyrexx mounting rod with claw holder for service providers RWM MC diagnostic device for an extended func...

Page 41: ...on class IP 40 Farbe Colour Kühlschrank Weiß Refrigerator white Material Material ABS Abmaße H x Ø Dimensions H x Ø 38 x 105 mm Gewicht Weight 156 g netto ohne Befestigungsmittel 156 g net without fasteners 268 g brutto Auslieferungszustand 268 g gross weight as delivered Auslesbarer Datenspeicher mit Exportfunktion Readable data storage with export function Vorhanden Available Montage Installatio...

Page 42: ...nweiston Inbetriebnahme Hinweiston Inbetriebnahme Start up alert tone Start up alert tone Aktivierungston Activation sound Hinweiston Instandhaltung Hinweiston Instandhaltung Maintenance alert tone Maintenance alert tone Prüfton Test tone Alarmtöne Alarmtöne Alarm tones Alarm tones Rauchalarm Smoke alarm Temperaturalarm Temperature alarm 0 5Sekunden Seconds 1 Sekunde Second 61 DE EN 12 Alarm und H...

Page 43: ...larmtöne im Normalbetrieb Optische und akustische Alarmtöne im Normalbetrieb Optical Optical and acoustical alarm tones in normal operating mode and acoustical alarm tones in normal operating mode Im Normalbetrieb sind keine optischen und akustischen Signaltöne zu hören No optical and acoustical signal tones are heard during normal operation Die Alarmtöne Rauchalarm und Temperaturalarm können Sie ...

Page 44: ...ste für 24 Stunden vorübergehend deaktivieren Das Gerät muss unbedingt ausgetauscht werden You can temporarily disable the alarm sounds battery alarm mes sage and contamination message for 24 hours by pressing the testing stop button It is necessary to replace the device 24 Stunden hours 18 Lichtsignale Light signals Lichtsignal Lichtsignal Light signal Light signal Beschreibung Description Interv...

Page 45: ... Pyrexx GmbH k_503132 Stand der Betriebsanleitung 2021 01 Änderungen vorbehalten Revision of the brochure 2021 01 Subject to change Impressum Pyrexx GmbH Siemensdamm 62 13627 Berlin Deutschland Germany ...