6.2 Pump Service
The high pressure water pump requires minimal maintenance. The pump oil level
should be checked on a regular basis. The pump crankcase holds 44 oz. (1.3 L)
of SAE 30 viscosity non-detergent oil. See pump manufacturer’s literature found
in the
APPENDIX
for further information.
6.3 Inspection/Cleaning of Water Inlet Strainer
The water inlet strainer and the water filter should be inspected before and after
each use of the CaviBlaster 2828-E60. To inspect and clean the strainer or filter,
follow the procedure below:
1) Turn the main power switch OFF and isolate or disconnect the water source
from the inlet connection to the power unit.
2) Unscrew the strainer bowl from the housing (turn CCW) (See Figure 6.1).
3) Pull the bowl down and remove the filter/strainer.
4) Inspect the filter/strainer and flush any debris clean with clean water.
5) Push filter/strainer back into housing and push the bowl back onto filter
housing.
6) Thread the bowl CW onto the housing nut to hand tighten.
7) Loosen and remove cap of main filter assy.
8) Lift filter media from housing and inspect for debris. Rinse or replace media
as necessary.
9) Inspect O-ring under the cap for damage. Replace cap and tighten.