5.6 Shutting Down the CaviBlaster
1. Stop the motor by turning the HPP motor switch, SW1, to the OFF position
(See Figure 2.2).
2. Turn the feed pump switch, SW2, to the OFF position (See Figure 2.2). If
using force feed from an alternate source or if using gravity feed, shut off the
supply of water to the pressure pump.
3. Turn the main switch to the OFF position.
4. Push in the E-Stop button.
5.
Squeeze the gun trigger to the open or “ON” position (See Figure 5.3) to
release the water pressure remaining in the hose(s)
while the gun is
submerged
.
6. It is now safe to remove the gun from the water.
7. Flush the system and rinse the power unit with fresh water at the end of the
day if the system has been used with seawater.
This space intentionally left blank
EOS
Page 26/35