3. Adjusting the Dot Alignment
This adjustment is made when the alignment of the print generated from left to right (outwards) does not
correspond with the print generated from right to left (inwards).
The acceptable range of displacement is a pitch of 1.
3-1 Adjustment A
1.
Generate a print sample to assess the range of displacement.
2.
Loosen the screw of the TM sensor board
3.
If the print generated from right to left is off to the right, move the TM sensor board in the direction
indicated by the arrow
1
. If the print is off to the left, move the TM sensor board in the direction
indicated by the arrow
2
.
4.
Tighten the screw of the TM sensor board.
5.
Generate another print sample. If the print is still out of alignment, go back to step 2 and repeat the
above process.
6.
If the print alignment does not improve, go to section 3-2 and go through the steps for Adjustment B.
Fig. 1-5 Adjustments A and B for dot alignment
Screw
Motor gear
Idol gear
Stop ring
TM sensor board
1
2
Summary of Contents for SP-1300
Page 1: ... without price TECHNICAL MANUAL TERMINAL SLIP PRINTER FEB 2000 SP 1300 INDEX ...
Page 20: ... 18 Fig 3 1 Lubricated Areas 1 ...
Page 21: ... 19 Fig 3 2 Lubricated Areas 2 ...
Page 23: ... 21 1 Printer Assembly 1 1 Disassembly Drawing ...
Page 25: ... 23 2 Printer Mechanism 2 1 Disassembly Drawing ...
Page 26: ... 24 ...
Page 30: ... 28 4 Wiring Scheme of Printer ...
Page 31: ... 29 5 Main Logic Board 5 1 Circuit Diagram Main Logic Board 1 5 ...
Page 32: ... 30 Main Logic Board 2 5 ...
Page 33: ... 31 Main Logic Board 3 5 ...
Page 34: ... 32 Main Logic Board 4 5 ...
Page 35: ... 33 Main Logic Board 5 5 ...