R-159
QT-6600 Reference Manual
4-23.
Time calculation
This function is used for time calculation (such as parking fee). Only PLU has this
capability. You should allocate the additional PLU program file (file-814).
And this function is only effective in the check tracking system.
Time calculation requires the following files:
PLU file
This file is used for registering item.
Unit price of this file is used for the first unit price.
Additional PLU program file
This file is used for time calculation. This file contains,
unit interval time “Interval (minutes)”, second time frame unit price “upper New Interval
Price”, number of unit interval time “upper Change Price After”,
third time frame unit price “lower New Interval Price”, number of unit interval time “lower
Change Price After”
and calculation method “Use Last Interval Price”.
Time calculation
There are two calculation methods.
• In case of setting “No” to “Use Last Interval Price”,
Total fee (case A) = @
1
* T
A
/ Interval time
Total fee (case B) = @
1
* T
F
/ Interval time +@
2
* (T
B
- T
F
)/ Interval time
Total fee (case C)
= @
1
* T
F
/ Interval time +@
2
* T
S
- T
F
/ Interval time + @
3
* (T
C
- T
S
- T
F
)/ Interval time
• In case of setting “Yes” to “Use Last Interval Price”,
Total fee (case A) = @
1
* T
A
/ Interval time
Total fee (case B) = @
2
* T
B
/ Interval time
Total fee (case C) = @
3
* T
C
/ Interval time
Case A
Case B
Case C
T
F
T
S
Unit price = @
1
Unit price = @
2
Unit price = @
3
In
In
In
Out 1
Out 2
Out 3
T
A
T
B
T
C
Example of receipt image
CHECK No.1
2 PLU0001
•25.00
12:00 -> 13:50
— Time frame
Summary of Contents for QT-6600
Page 1: ...QT 6600 Touch Screen Smart Terminal Reference Manual Version 1 1 December 2008 c C C ...
Page 67: ...R 67 QT 6600 Reference Manual ...
Page 136: ...R 136 Manager Operation ...
Page 181: ...R 181 QT 6600 Reference Manual A 1 Function key list R 182 ...
Page 222: ...R 222 File Format ...
Page 226: ...R 226 Calculation method ...
Page 234: ...R 234 Error messages ...