No
Operation
Display
Inspection contents
– 46 –
Back to Main Menu 1
Tap [Exit]
or
push "Enter" key.
No.7 Sensor_1
Tap "7.Sensor"
or
push "7" key.
Tap "1.Sensor1"
or
push "1" key.
** Sensor1 **
Battery Voltage (GLOB)
xxx
LCD Temperature (GLOB)
xxx
CPU Temperature (GLOB)
xxx
Bright Sensor (GLOB)
xx
[Exit] or Enter Key
Confirm the Battery Voltage
(GLOB) value.
Confirm the LCD Temperature
(GLOB) value.
Confirm the CPU Temperature
(GLOB) value.
The Battery Voltage (GLOB)
value must be in
500 - 600
.
The LCD Temperature (GLOB)
value must be in
150 - 350
.
The CPU Temperature (GLOB)
value must be in
150 - 350
.
_
Confirm the display on the left.
_
** Sensor **
1.Sensor1
2.Sensor2
[Exit] or Enter Key
Block the illuminance sensor
lens.
Confirm the Bright Sensor
(GLOB) value.
** Sensor1 **
Battery Voltage (GLOB)
xxx
LCD Temperature (GLOB)
xxx
CPU Temperature (GLOB)
xxx
Bright Sensor (GLOB)
xx
[Exit] or Enter Key
** Sensor1 **
Battery Voltage (GLOB)
xxx
LCD Temperature (GLOB)
xxx
CPU Temperature (GLOB)
xxx
Bright Sensor (GLOB)
xx
[Exit] or Enter Key
1
2
3
4
5
The measured Bright Sensor
(GLOB) value should be
10 or less
.