7 - MAINTENANCE
Resetting the Selective Catalytic Reduction (SCR) system
For
DEF/A
D
B
LUE
®
storage tank fluid level faults, failures which can cause engine power loss, perform as follows:
• Raise the
DEF/A
D
B
LUE
®
tank level above
15%
of the total volume.
• Cycle the key switch to the OFF position or return the throttle to low idle position.
For
DEF/A
D
B
LUE
®
quality and SCR system technical faults, failures which can cause engine power loss, read
the following:
• To fully reset the system, repair or replace the component/failure causing the fault.
• Switching off the engine will reset the system and the engine will restart at full power.
• If the same failure is re-detected within
40 h
of engine operation, the last active engine power loss level will be
activated.
• If the same failure is detected three consecutive times within
40 h
of engine operation, maximum engine power loss
will remain active after engine restart until the system is repaired.
• Please contact your authorized CASE CONSTRUCTION dealer for service.
7-22
Summary of Contents for 621G Stage IV
Page 42: ...2 SAFETY INFORMATION Empty tool LEEN11T0024AA 20 2 22 ...
Page 60: ...2 SAFETY INFORMATION 2 40 ...
Page 137: ...3 CONTROLS AND INSTRUMENTS Inducement and validation re starts LEIL14WHL0394HA 2 3 77 ...
Page 138: ...3 CONTROLS AND INSTRUMENTS Validation re start procedure LEIL15WHL0608HA 3 3 78 ...
Page 150: ...3 CONTROLS AND INSTRUMENTS 3 90 ...
Page 166: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 7 4 16 ...
Page 168: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 9 4 18 ...
Page 170: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 12 4 20 ...
Page 208: ...6 WORKING OPERATIONS 6 18 ...
Page 229: ...7 MAINTENANCE DEF AdBlue technical faults LEIL14WHL0392HA 4 7 21 ...
Page 370: ...7 MAINTENANCE 7 162 ...