6871082-R2
1
GA0380.eps
A
GA0028.eps
TRUCK REQUIREMENTS
GA0082.eps
Carriage Mount Dimension (A)
ITA (ISO)
Minimum
Maximum
Class II
Class III
14.94 in. (380.0 mm)
18.68 in. (474.5 mm)
15.00 in. (381.0 mm)
18.74 in. (476.0 mm)
WARNING:
Rated capacity of the truck/attachment
combination is a responsibility of the original truck
manufacturer and may be less than that shown on the
attachment nameplate. Consult the truck nameplate.
Clamp
Sideshift
Right
Hoist Up
Auxiliary Valve Functions
Check for compliance with ANSI/ITSDF (ISO) standards:
Tilt Back
Hoist Down
Sideshift
Left
Tilt
Forward
Release
STANDARD CARTON CLAMP & WHITE GOODS CLAMPS
Carriage –
Clean carriage bars and
inspect carriage bars. Make sure the
bars are parallel and that ends are
flush. Repair any damaged notches.
Truck Relief Setting
(see attachment nameplate)
Low Pressure
High Pressure
2245 psi (155 bar) 2755 psi (190 bar) -
Recommended
2740 psi (189 bar) 3625 psi (250 bar) -
Maximum
NOTE:
The attachment valve has separate pressure
relief control for CLAMP and SIDESHIFT functions, see
Installation Step 11 for adjustment.
Truck Flow Volume
➀
8J-26J
Min.
➁
Recommended
Max.
➂
SIDESHIFT
1 GPM
(4 L/min.)
5 GPM
(19 L/min.)
10 GPM
(38 L/min.)
CLAMP
5 GPM
(19 L/min.)
12 GPM
(45 L/min.)
16 GPM
(61 L/min.)
➀
Cascade J-Series Carton Clamps are compatible with SAE 10W
petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-5606 or
MIL-0-2104B. Use of synthetic or aqueous base hydraulic fluid
is not recommended. If fire resistant hydraulic fluid is required,
special seals must be used. Contact Cascade.
➁
Flow less than recommended will result in reduced system
performance.
➂
Flow greater than maximum can result in excessive heating,
reduced system performance and short hydraulic system life.