12
6033701-R9 EN
CONTACT PAD EXTENSION
CARTON CLAMPS
CL5658.eps
Attachments supplied with contact pad extensions are
installed as follows:
1
Install pivot block to contact pad. Tighten capscrews
to 90 Nm.
2
Loosen lever on pivot block. Position the lever to the
front face of the pivot block.
3
Insert the lower lock plate into the pad extension.
4
Install pad extension to contact pad. Tighten
capscrews to 90 Nm. The pad extension lock flange
should be flush with the top of the pivot block.
5
Position the lever to the top face of the pad extension
lock flange.
6
Adjust the lock lever to firmly clamp the lock flange to
the pivot block when in the lock position.
7
Fully lock the lever by positioning the lever in the
downward position.
NOTE:
The face of the pad extension should be flush with
the contact pad surface. Shim as required.
CL5645.eps
4
6
7
4
3
1
2
5
Shim
Pad Extension
Contact Pad
Lever
Pivot Block
Pad Extension
Lock Flange
Lower
Lock
Plate
NOTE:
If the pad extension
assembly is removed, install
the lower lock plate with the
pivot block.