background image

11

M

M

M

M

M

IDDLE

IDDLE

IDDLE

IDDLE

IDDLEB

B

B

B

BUR

UR

UR

UR

URY

Y

Y

Y

Y

Send Signal

LED

Fan Control

To start the fan. Press the selected speed button to run the fan at the desired speed.

LOW=Low speed    MED=Medium speed     HIGH=High speed

To turn off the fan, press the 

FAN OFF

  button.

Airflow Direction

To reverse the airflow, press the 

REVERSE 

button. 

REVERSE 

operates at any speed

whether the fan is on or off. The fan returns to its set speed after reversing.

Light Control

Turn the light on or off independently from the fan by pressing the 

 LIGHT 

rocker

switch. (Press the left side for the uplight, right side for the downlight, and the middle for
both.) If you press the button for more than 0.7 seconds, it becomes a dimmer. The light
varies from “bright" to “dim” over approximately 8 seconds. If you continue to hold the

LIGHT

 button, this sequence will reverse when the light reaches its brightest or dimmest

level. Release the button when the desired level is reached.

Auto Resume

Quick (pressing less than 0.7 seconds) on/off operation of the 

LIGHT

 button maintains

the desired brightness level set previously.

If the fan is not functioning after installation:

Step 1.

 Check to make sure the batteries are installed correctly in

the control.

Step 2.

 Turn the power off to the fan (from the circuit breaker)

for at least 5 seconds.

Step 3.

 Turn the power back on (at the circuit breaker) and push

the 

HIGH

MED

, and 

LOW 

buttons–in that order–within 20

seconds. The fan should now function properly.

CHANGING TRANSMITTER FREQUENCY SETTING

You will only have to change the dip switch settings in the remote
if you are using more than one fan in the same area and want to
control them separately.

Step 1.

 At the circuit breaker or fuse box, turn the power off for

the fan you want to change.

Step 2.

 Open the battery door of the Versa•Touch control and

remove the batteries.

Step 3.

 Change the dip switch settings, assuring that they are

different from the previously installed Versa•Touch fan.

Step 4.

 Reinstall the batteries and the battery door on the control.

Step 5.

 At the circuit breaker or fuse box, turn the power back on

for the fan whose frequency you are changing.

Step 6.

 Within 20 seconds of restoring power, push the 

HIGH

,

MED

, and 

LOW 

buttons (in that order).

Circuit Breaker

or Fuse Box

Press in this order to set new

frequency:

1. HIGH     2. MED      3. LOW

Dip Switch

set to “01001”

Dip Switch

set to “10000”

Versa•Touch 2

Control

(back)

LOW

MED

HIGH

DOWNLIGHT

FAN

OFF

REVERSE

1

2

3

Note:

 You may want to label your controls to assure you do not

mix them up.

REMOTE OPERATION

WARNING!

Do not turn the power off at the circuit breaker,
then back on, for the previousl y installed
Versa•Touch2 fan(s), as you may inadvertently
change the frequency settings for it as well.

Note:

 All fans leave the factory set to “00000.”

UPLIGHT

Summary of Contents for MIDDLEBURY

Page 1: ...on procedure MIDDLEBURY Owner s Manual READ AND SAVE THESE INSTRUCTIONS CONTENTS INTRODUCTION Before You Start 2 Safe Use 2 MOUNTING RECOMMENDATIONS General Guidelines 3 Sloped Ceiling Installations 3...

Page 2: ...the canopy hatch make sure all wires are within the canopy and that no wires are being pinched Unpacking Before assembling and installing your ceiling fan remove all parts from the shipping cartons a...

Page 3: ...f Ceiling Angle Use the tear off Ceiling Angle Template card inserted in this manual It provides you with a simple go or no go for installing your fan on a sloped ceiling When to Use Extension Poles F...

Page 4: ...R MOUNTING BRACKET INSTALLATION Note After removing the old fixture check the outlet box to insure that it is supported by a joist or beam across its upper surface If not a 2x4 stud must be installed...

Page 5: ...ket and screw into the guide hole Tighten until the outlet box is mounted firmly to the beam This box must be secured to the ceiling firmly Step 3 Attach the canopy to the crossbar mounting bracket wi...

Page 6: ...Before starting the installation of your ceiling fan install the threaded downrod into the motor coupling and lock the assembly CAUTION Failure to fully lock in the downrod before securely tightening...

Page 7: ...e and screws as shown Do not discard the two screws They will be used to reinstall the plate later Step 7b Attach the blade bladeholder assembly to the motor by using two bladeholder screws from Pack...

Page 8: ...er source Secure with wire nut WHITE wire from fan to white NEUTRAL wire in ceiling fixture outlet box Secure with wire nut BLACK power wire from fan to black POWER wire in ceiling outlet box Secure w...

Page 9: ...th the three screws Step 11d Securely tighten all three screws by hand only using the provided screwdriver Install Incandescent Lightbulbs Step 12 Screw in two 60 watt type A15 medium base lightbulbs...

Page 10: ...e switch Step D Insert and tighten the screws using the provided screwdriver Outer mounting holes Control Bracket Rocker Light Switch Switch Cover Plate Wall Installation Step A Locate a 2x4 wall stud...

Page 11: ...aker for at least 5 seconds Step 3 Turn the power back on at the circuit breaker and push the HIGH MED and LOW buttons in that order within 20 seconds The fan should now function properly CHANGINGTRAN...

Page 12: ...mounting plate assembly Make sure the wire nuts inside the canopy and switch housing are not touching the metal parts and that they have not fallen off the wire splices Tighten as necessary Tighten th...

Page 13: ...omplies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received includin...

Page 14: ...80538 FIRESIDE LIGHTING INC 970 669 3540 OWTS COLORADO SPRINGS 80903 HOME LIGHTING INC 719 471 3520 OWTS FORT COLLINS 80525 THE LIGHT CENTER 970 226 3430 OWTS LONGMONT 80501 LUMENAREA COM INC 303 485...

Page 15: ...HILLS ELECTRIC INC 402 691 4567 STATE CITY ZIP SERVICE CENTER NAME PHONE TYPE NORFOLK 68701 THE POWER STATION FROHBERG ELEC 402 371 6671 LINCOLN 68510 LINCOLN LIGHTING CTR 402 476 1297 NEVADA SPARKS 8...

Page 16: ...4704 GIDDINGS 78942 ORSAG S INC 409 542 3167 LUBBOCK 79413 ORECK VACUUMS 806 792 2821 STATE CITY ZIP SERVICE CENTER NAME PHONE TYPE ARLINGTON 76001 P M QUALITY CONT 817 478 2004 TYLER 75707 CHARLES R...

Reviews: