14
15
SPECIFICATIONS
(SW-1S/1C)
MODEL
Capacity / e
Internal Resolution
External Resolution
Display
Symbols
Keys
Functions
Dimensions
Platter size
Weight
Power
Battery Life
Operating Temperature
Option
SW 1S/1C- 02 SW 1S/1C- 05 SW 1S/1C- 10 SW 1S/1C- 20
2kg/O.O01kg 5kg /0.002kg 10kg/0.005kg
20kg/0.01kg
5 lb/0.002 lb
10 lb/0.005 lb 20 lb/0.01 lb 30 lb/0.02 lb
80oz/0.05oz 160oz/0.1oz 400oz/0.2oz 800oz/0.5oz
1/20,000 1/25,000 1/20,000 1/20,000
1/2,000 1/2,500 1/2,000 1/2,000
110
35[mm]/43"
13.8" 5 digit LCD
STABLE, ZERO, TARE, HI/OK/LO, PCS, g, kg, lb, oz, Low Battery
HI/OK/LO & PCS (SW-1C only)
ZERO, TARE, HOLD(SW-1S only), MODE(SW-1C only), POWER
Weighing
Hold Function (SW-1S only)
Counting-Counting SampleRange : 10~100,200,300,400,500 (SW-1C only)
Weight Comparison Function : hi, ok, low(SW-1C only)
Weight Unit Conversion Function : kg, lb, oz
260(W)
287(D)
137(H)[mm]/
102(W)
113(D)
54(H)[inch]
230(W)
190(D)[mm]/90.55(W)
74.80(D)[inch]
2.8 kg
1.5 V
6 units (D size Battery) or 9 V Adapter
Approx. 800 hours (Manganese battery)/
1600 hours (Alkaline at 20°C /68°F)
10°C
40°C / 14°F
104°F
9 V Adapter 300mA, Rear Display , Stainless Tray
Notice: Specifications are subject to change for improvement
without notice.
ERROR MESSAGE
An error of the initial zero range
Problems on Analog Module
Overload on the platter
Unstable conditions of scale
Set the platter empty.
Try to turn OFF and ON the scale.
Call your CAS dealer if still problems.
Remove it from the platter
Do not put somthing exceeding maximum
capacity on the platter
Make the scale stable conditions
ERROR REASONS
SOLUTIONS
Err
Init
OFL
UNStA
BATTERY MAINTENACE
LOW BATTERY WARNING
When the battery is low the display shows the "BAT" sign.
You can replace the battery new one.
If you still use the scale without replacing the battery the scale may provide
incorrect result on measurement.