background image

Press

key once to set

up the low limit. The display
shows "0.000" and the first  
number flashes.

Press the

key until 

the display shows "WL
OFF". "WL OFF" means 
that comparator function
is not activated.

11

10

Press

key to activate 

this function. The display
shows "WL ON".

LO

5. Comparator Function - HI / LOW Limit Setting (SW-1C only) 

Press the

key to have

number increase. To move
flash to next digit, press 
the

key.

Press

key to set up HIGH

limit. The display shows
"0.000" and you can change
these numbers by pressing        

key. If you want to move

to next digit you can go by
pressing

key.

If you set up HIGH limit you 
can go out by pressing
key, and you can see "ENd" 
message shortly and "WL 
on" message on the display.

LO

HI

If you set up HIGH limit and LOW limit incorrectly, "Err" will be shown on the display. 
Then you may need to set it up again. For example, LOW LIMIT=2.990 kg and HIGH
LIMIT=1.990 kg this is incorrect setting because HIGH limit is lower than the LOW limit. 
When HIGH and LOW limit are set as the same or above maximum capacity it still shows 
"Err" message.

If you want to go back to the 
simple weighing mode just
press

key twice.

Suppose that the HIGH limit and 
LOW limit are set up as 2.990kg 
and 1,990kg respectively. If the
weight loaded is 2kg between
HIGH and LOW limit the display
shows "OK" and the scale
continues to beep slowly.
If the weight loaded is above 
2.990kg, HIGH limit, the scale 
continues to beep rapidly.

LO

OK

kg

kg

6. Counting Function 

(SW-1C only)

Counting without Tare

Initial display as above.

Press

key twice to go

to sample unit selection
mode. 

Press

key to select the

number of sample unit. You
can select 10, 20, 30, 40,
50,60, 70, 80, 90, 100, 200,
300,400, or 500 as a sample
unit.

kg

pcs

pcs

Summary of Contents for SW-1S Series

Page 1: ...9002 SW6 0033 0 2003 10 SW 1S 1CSeries Simple Weighing Scale OWNER S MANUAL...

Page 2: ...ERATIONS 8 1 SimpleWeighingMode 8 2 WeighingwithTare 8 3 ChangingUnitofWeight 9 4 HoldFunction SW 1Sonly 9 5 ComparatorFunction SW 1Conly 10 6 CountingFunction SW 1Conly 11 7 Auto PowerOffFunction 13...

Page 3: ...tely for proper repair Do not overload beyond the maximum weight limit Do not pull the plug by its cord when unplugging Damaged cord could cause electric shock or fire To prevent from fire occurring D...

Page 4: ...and care of the SW 1S 1C Series Please keep it handy for future reference OVERALL VIEW PLATTER DISPLAY ADJUSTING BOLT KEYBOARD KEY FUNCTIONS SW 1C Used to set the zero point Used to input or cancel th...

Page 5: ...container from full weight loaded kg kg Place a container on the platter Press the key Place a commodity into the container then the display will show only the weight of the commodity kg kg kg Remove...

Page 6: ...ly Err will be shown on the display Then you may need to set it up again For example LOW LIMIT 2 990 kg and HIGH LIMIT 1 990 kg this is incorrect setting because HIGH limit is lower than the LOW limit...

Page 7: ...the number on display Remove all of commodities from the scale pcs pcs Counting with Tare Press key twice to go to sample unit selection mode PCS is shown on the display then press key to select the n...

Page 8: ...nction kg lb oz 260 W 287 D 137 H mm 102 W 113 D 54 H inch 230 W 190 D mm 90 55 W 74 80 D inch 2 8kg 1 5V 6 units D size Battery or 9V Adapter Approx 800hours Manganese battery 1600hours Alkaline at 2...

Reviews: