7. How to Set Auto Power Off
Auto-Power off function is to automatically power off as time is set. This
function is helpful to save battery, which is not in use. The following is the
setting procedure of Auto-power off.
When the scale is turned off
press
key, holding
key. Then you will see the
"AP-10".(If you have set this
before,display will show
previous value.)
Press the
key until the
display shows the "AP-x0"
that you wish to take.
(Refer to TABLE 1.)
Press the
key, and then
the scale saves what you
programmed and shows all
the segments, counting up
"0" to "9".
kg
DISPLAY FUNCTION
AP-00
This function does not automatically power off.
AP-10
This function does automatically power off when the scale is not in use for 10 minutes.
AP-20
This function does automatically power off when the scale is not in use for 20 minutes.
AP-30
This function does automatically power off when the scale is not in use for 30 minutes.
TABLE 1.
Put all of commodities you
wish to count, and then
count the number on display.
Remove all of commodities
from the scale.
pcs
pcs
Counting with Tare
Press
key twice to go to
sample unit selection mode.
"PCS" is shown on the display,
then press
key to select
the number of sample unit.
Put the container on the
scale and press
key to
set weight of tare.You can
select 10, 20, 30, 40, 50,
60, 70, 80, 90, 100,200,
300,400, or 500 as a sample
unit, by pressing
key.
If the number of selected
sample unit is 20, please
put 20 sample units on the
scale.Then press
key
to set unit weight.
pcs
pcs
pcs
If you select "P_10" as a
sample unit, then please
put 10 sample units on the
scale. Then press
key
to set sample units.
Put all of commodities you
wish to count, and then
check the number of pieces
on display.
Remove all of commodities
from the scale.
pcs
pcs
pcs
When you try to set the number of sample unit at the
stage the display may show "LACK"
message shortly. The result of counting may be incorrect in the following cases.
a.unit weight
1/2 e *
b.weight loaded
2% of maximum weighting capacity.
*"e" value may be various on capacity of product model.
Please refer to "SPECIFICATION" on page 15. For example, a product model
which capacity is 2.000kg has 1g as "e" value