19
2) TRANSMISSION PROCEDURE
(1) PD-II sends data to External Device whenever weight is changed after receiving <W> signal
from the External Device.
(2) PD-II stops sending data when receives <CR> signal from the External Device.
External Device
<W> ------
----- DATA (If weight is changed)
------ DATA (If weight is changed)
<CR> ------
Stop transmitting data
3.1.3. TYPE-0 and TYPE-1 INTERFACE
Most P.O.S Systems, ECRs and some TEC P.O.S Systems.
1) PROTOCOL
EXTERNAL DEVICE
SCALE(PD-II)
<ENQ> ------------ Initiate
communication
<DC2> ------------
Request of weight data
------------ <ACK>
:
Acknowledge the request of weight data
Inquiry
------------
<STX>
: Start Transmission
------------ <ID>
:
Scale type identifier
------------
<W5>
: Weight data
------------
<W4>
: Weight data
------------
<W3>
: Weight data
------------
<W2>
: Weight data
------------
<W1>
: Weight data
------------
<BCC>
: Block Check Character
------------
<ETX>
: End Transmission
Summary of Contents for PD-II
Page 1: ...1 PD II MANUAL ...
Page 7: ...7 1 4 Sealing Method ...
Page 14: ...14 8 You can change the mode by pressing TARE or lb kg key ...
Page 38: ...38 4 4 Parts Location 4 4 1 Main and Power Part 4 4 1 1 TOP 4 4 1 2 Bottom ...
Page 39: ...39 4 4 2 Display Part 4 4 2 1 Top 4 4 2 2 Bottom ...
Page 40: ......
Page 41: ...41 5 EXPLODED VIEW ...
Page 42: ...42 ...