67
▶
Indicator Data Transmission Format (Includes BCC)
STX(1) ID.NO.(2) COMMAND(4) ACK(1) BCC(2) ETX(1)
STX
ID.NO.
WZER
ACK
AF(BCC)
ETX
2H
30H
31H
57H
5AH
45H
52H
06H
41H
46H
03H
● ACK :06H = Transmission Complete (Normal Operation) , NAK : 15H Transmission
Unsuccessful (Re-transmit)
● BCC : 30H + 31H + 57H + 5AH + 45H + 52H + 06H= 1AFH
▶
Indicator Data Transmission Format (Excepts BCC)
STX(1) ID.NO.(2) COMMAND(4) ACK(1) ETX(1)
STX
ID.NO.
WZER
ACK
ETX
2H
30H
31H
57H
5AH
45H
52H
06H
03H
● ACK : 06H = Transmission Complete (Normal Operation) , NAK : 15H Transmission
Unsuccessful (Re-transmit)
※ DATA1 (16)
1. Header1
ST = Stable, US = Unstable, OL = Over Load
2. Header2
NT = Net Weight , GS = Gross Weight
3. DATA
Weight including code and decimals
4. UNIT
Kg = kg, Ton = t.
STX
(1)
ID.NO
(2)
COMMAND
(4)
DATA
(16)
BCC
(2)
ETX
(1)
Header1
(2)
,(1)
Header2 (2)
,(1)
DATA (8)
UNIT (2)