7
TECHNICAL SPECIFICATION
Analog Part & A/D Conversion
Load cell excitation
voltage
DC 5 V
Zero adjust range
0.05 mV
∼
5 mV
Input sensitivity
0.2 uV/D (Non-certification)
0.36 uV/D (Certification)
Nonlinearity
0.01 % F.S.
A/D internal resolution
1/1,000,000
A/D external resolution
1/30,000(Max.)
A/D conversion speed
320 times/sec
Digital Part
Span calibration
Full Digital Calibration
(Single pass automatic span calibration)
Input noise
below ±0.3μVpp
Input impedance
over 10MΩ
Display
7 Segment(6 digit)
Maximum capacity
999999
Division
×
2, ×5, ×10, ×20, ×50
Display below zero
“-“ minus signal
Permitted limit tare
Full capacity
Display Part
Description
“STABLE”
■
LAMP
Weight is stable
“TARE”
■
LAMP
Tare is used
“NET”
■
LAMP
ON(NET weight), OFF(GROSS weight)
“HOLD”
■
LAMP
Hold in Weight
“ZERO”
■
LAMP
“0” kg
“kg”
■
LAMP
Use unit kg
“t”
■
LAMP
Use unit ton
Summary of Contents for CI-170A
Page 1: ...2 ...
Page 3: ...4 ...
Page 4: ...5 ...
Page 8: ...9 MEASURE OF APPEARANCE ...
Page 76: ...77 MEMO ...
Page 77: ...78 MEMO ...
Page 78: ...79 MEMO ...
Page 79: ...80 ...