41
Menu-AOUT.06: Maximum weight of A-out
Function
Maximum Output Weight Value upon Using Analog Out option
Set Range
(0 ~ Max weight)
Display Part
Meaning
1000
2000
Initial value : Max weight
Maximum output at 1000 kg
Maximum output at 2000 kg
Menu-AOUT.07: Adjust zero of A-out
Function
Adjust the Zero Output upon Using Analog Out option
Set Range
(0 ~ 24000)
Display Part
Meaning
0000
0.000mA, 0V output
4000
4.000mA, 2V output
4015
4.015mA, 2.007V output
Note 1. The example is based on settings of 0~10V, 0~24mA.
Note 2. The Micro-adjustment function does not work during simultaneous output of V-out and I-out.
Menu-AOUT.08: Adjust Span of A-out
Function
Adjust the Maximum Output upon Using Analog Out option
Set Range
(0 ~ 24000)
Display Part
Meaning
10000
10.000 mA, 4.16 V output
20000
20.000 mA, 8.33 V output
24000
24.000 mA, 10.0 V output
Note 1. The example is based on settings of 0~10V, 0~24mA.
Note 2. The Micro-adjustment function does not work during simultaneous output of V-out and I-out.
Menu-AOUT.09: Set A-out Output Type
Function
Set A-out Output Type
Set Range
(0 ~ 2)
Display Part
Meaning
ATYP. 0
Displayed value output
ATYP. 1
Gross Weight output
ATYP. 2
Net weight output